In vitro detection of cavitation induced by a diagnostic ultrasound system
- 1 January 1992
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 39 (1) , 95-101
- https://doi.org/10.1109/58.166815
Abstract
Experiments were performed to determine whether a clinical diagnostic scanner, a Hewlett-Packard (HP) 77020A, could produce cavitation in water containing suspensions of either 0.245- mu m polystyrene spheres or Albunex, 1-10 mu m albumin-coated microbubbles. Two calibrated, phased-array HP imaging transducers with 2.5- and 5.0-MHz operating frequencies were driven in M-mode (single cycle) and Doppler mode 4 cycles by the HP imaging system. Cavitation was detected in the water with polystyrene spheres at 2.5 MHz in both M-mode and Doppler mode at a peak negative acoustic pressure of 1.1 MPa or greater. Insonification at 5.0 MHz in either mode did not produce a detectable amount of cavitation, even with peak negative pressures as high as 1.2 MPa. Cavitation was not detected in water with the Albunex spheres at either frequency.<>Keywords
This publication has 18 references indexed in Scilit:
- A comparison between “real” and “ideal” gas in theoretical cavitation dynamicsThe Journal of the Acoustical Society of America, 1991
- Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environmentThe Journal of the Acoustical Society of America, 1990
- An acoustic backscattering technique for the detection of transient cavitation produced by microsecond pulses of ultrasoundThe Journal of the Acoustical Society of America, 1990
- The detection of microbubble radius versus time and some comparisons with theoretical resultsThe Journal of the Acoustical Society of America, 1990
- Thresholds for cavitation produced in water by pulsed ultrasoundUltrasonics, 1988
- Epidemiology of human exposure to ultrasound: A critical reviewUltrasound in Medicine & Biology, 1988
- A survey of the acoustic output of ultrasonic Doppler equipmentClinical Physics and Physiological Measurement, 1987
- The output of pulse-echo ultrasound equipment: a survey of powers, pressures and intensitiesThe British Journal of Radiology, 1985
- Evidence for ultrasonic finite-amplitude distortion in muscle using medical equipmentThe Journal of the Acoustical Society of America, 1985
- Cavitation dynamics. I. A mathematical formulationThe Journal of the Acoustical Society of America, 1975