Clinical Relevance of Accuracy of Pedicle Screw Placement
- 15 October 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 23 (20) , 2215-2220
- https://doi.org/10.1097/00007632-199810150-00014
Abstract
Study Design. The location of pedicle screws (n = 244) and the increase in the pedicle diameter were determined by computed tomography after screw removal in 50 patients with 360° lumbar fusions. The neurologic findings were examined before and after surgery. Objectives. To evaluate the correlation between the accuracy of pedicle screw placement and preoperative and postoperative neurologic findings. Summary of Background Data. Incorrect placement of pedicle screws that was detected by computed tomography has been published in several studies. Simultaneous pathologic neurologic deficits are thought to be created by an eccentric screw track. Methods. Two observers controlled the screw tracts and pedicle diameters. The results were compared with preoperative and postoperative neurologic findings. Results. Fifty-nine percent (144 of 244) of screws were placed centrally in the pedicle. More than half of the eccentric screws (100, 41%; medial 79, 32.4%; lateral 21, 8.6%) penetrated the pedicle wall less than 2 mm (51; 20.9%). In only one patient (0.5%) a radicular irritation was found without objective electrophysiologic correlation when the screw was more than 6 mm medial to the pedicle wall. After screw removal, an insignificant increase in the size of the pedicle diameter in L1-S1 was noted. Conclusions. Experienced surgeons implant pedicle screws with an accuracy of approximately 80%. The accuracy could be improved by using image-guided insertion equipment. The neurologic symptoms are rarely influenced by an eccentric pedicle screw tract even if penetration of the pedicle wall is more than 6 mm. The results stress the importance of preoperative planning (pedicle diameter, pedicle angle, screw length) when implanting transpedicular fixators.Keywords
This publication has 14 references indexed in Scilit:
- Accuracy of Pedicle Screw Placement in Lumbar VertebraeSpine, 1996
- Image-Guided Insertion of Transpedicular ScrewsSpine, 1995
- CT Analysis of Pedicles and Screw Tracts After Implant Removal in Thoracolumbar FracturesJournal of Spinal Disorders, 1993
- Lagekontrolle von Pedikelschrauben nach instrumentierter dorsaler Fusion der LendenwirbelsäuleZeitschrift für Orthopädie und ihre Grenzgebiete, 1992
- Der Fixateur interne bei nicht-traumatischen Indikationen in der Wirbelsäulen-ChirurgieZeitschrift für Orthopädie und ihre Grenzgebiete, 1991
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990
- Roentgenographic Measurement of Pedicle Screw PenetrationClinical Orthopaedics and Related Research, 1989
- Spinal Pedicle Fixation: Reliability and Validity of Roentgenogram-Based Assessment and Surgical Factors on Successful Screw PlacementSpine, 1988
- Internal Fixation of the Lumbar Spine with Pedicle Screw PlatingClinical Orthopaedics and Related Research, 1986
- The value of postural reduction in the initial management of closed injuries of the spine with paraplegia and tetraplegiaSpinal Cord, 1969