Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons
Open Access
- 1 January 2003
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 4 (1) , 25-39
- https://doi.org/10.1120/jacmp.v4i1.2539
Abstract
In this study, a dosimetric evaluation of the new Kodak extended dose range (EDR) film versus ionization measurements has been conducted in homogeneous solid water and water‐lung equivalent layered heterogeneous phantoms for a relevant range of field sizes (up to a field size of 25×25 cm2 and a depth of 15 cm) for 6 and 15 MV photon beams from a linear accelerator. The optical density of EDR film was found to be linear up to about 350 cGy and over‐responded for larger fields and depths (5% for 25×25 cm2 at depth of 15 cm compared to a 10×10 cm2, 5 cm depth reference value). Central axis depth dose measurements in solid water with the film in a perpendicular orientation were within 2% of the Wellhöfer IC‐10 measurements for the smaller field sizes. A maximum discrepancy of 8.4% and 3.9% was found for the 25×25 cm2 field at 15 cm depth for 6 and 15 MV photons, respectively (with curve normalization at a depth of 5 cm). Compared to IC‐10 measurements, film measured central axis depth dose inside the lung slab showed a slight over‐response (at most 2%). At a depth of 15 cm in the lung phantom the over‐response was found to be 7.4% and 3.7% for the 25×25 cm2 field for 6 and 15 MV photons, respectively. When results were presented as correction factors, the discrepancy between the IC‐10 and the EDR was greatest for the lowest energy and the largest field size. The effect of the finite size of the ion chamber was most evident at smaller field sizes where profile differences versus film were observed in the penumbral region. These differences were reduced at larger field sizes and in situations where lateral electron transport resulted in a lateral spread of the beam, such as inside lung material. Film profiles across a lung tumor geometry phantom agreed with the IC‐10 chamber within the experimental uncertainties. From this investigation EDR film appears to be a useful medium for relative dosimetry in higher dose ranges in both water and lung equivalent material for moderate field sizes and depths. © 2003 American College of Medical Physics.Keywords
Funding Information
- National Institutes of Health (P01-CA59827)
This publication has 44 references indexed in Scilit:
- Dose escalation for non-small cell lung cancer using conformal radiation therapyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- A volumetric study of measurements and calculations of lung density corrections for 6 and 18 MV photonsInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Two-dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beamsMedical Physics, 1997
- Effect of low-density lateral interfaces on soft-tissue dosesInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Film dosimetry in water in a 23 MV therapeutic photon beamRadiotherapy and Oncology, 1995
- Evaluation of lung dose correction methods for photon irradiations of thorax phantomsInternational Journal of Radiation Oncology*Biology*Physics, 1989
- The influence of ionization chamber and phantom design on the measurement of lung dose in photon beamsMedical Physics, 1988
- Benchmark measurements for lung dose corrections for x-ray beamsInternational Journal of Radiation Oncology*Biology*Physics, 1988
- Effects of ionization chamber construction on dose measurements in a heterogeneityMedical Physics, 1987
- Calculation and Application of Point Spread Functions for Treatment Planning with High Energy Photon BeamsActa Oncologica, 1987