A dual mesh scheme for finite element based reconstruction algorithms
- 1 January 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 14 (3) , 504-514
- https://doi.org/10.1109/42.414616
Abstract
The finite element (FE) method has found several applications in emerging imaging modalities, especially microwave imaging which has been shown to be potentially useful in a number of areas including thermal estimation. In monitoring temperature distributions, the biological phenomena of temperature variations of tissue dielectric properties is exploited. By imaging these properties and their changes during such therapies as hyperthermia, temperature distributions can be deduced using difference imaging techniques. The authors focus on a microwave imaging problem where the hybrid element (HE) method is used in conjunction with a dual mesh scheme in an effort to image complex wavenumbers, k(2). The dual mesh scheme is introduced to improve the reconstructed images of tissue properties and is ideally suited for systems using FE methods as their computational base. Since the electric fields typically vary rapidly over a given body when irradiated by high-frequency electromagnetic sources, a dense mesh is needed for these fields to be accurately represented. Conversely, k(2) may be fairly constant over subregions of the body which would allow for a less dense sampling of this parameter in those regions. In the dual mesh system employed, the first mesh, which is uniformly dense, is used for calculating the electric fields over the body whereas the second mesh, which is nonuniform and less dense, is used for representing the k(2) distribution within the region of interest. The authors examine the 2-D TM polarization case for a pair of dielectric distributions on both a large and small problem to demonstrate the flexibility of the dual mesh method along with some of the difficulties associated with larger imaging problems. Results demonstrate the capabilities of the dual mesh concept in comparison to a single mesh approach for a variety of test cases, suggesting that the dual mesh method is critical for FE based image reconstruction where rapidly varying physical quantities are used to recover smoother property profiles, as can occur in microwave imaging of biological bodies.Keywords
This publication has 16 references indexed in Scilit:
- An active microwave imaging system for reconstruction of 2-D electrical property distributionsIEEE Transactions on Biomedical Engineering, 1995
- Temperature field estimation using electrical impedance profiling methods. I. Reconstruction algorithm and simulated resultsInternational Journal of Hyperthermia, 1994
- Conjugate direction methods for helmholtz problems with complex‐valued wavenumbersInternational Journal for Numerical Methods in Engineering, 1992
- Planar and cylindrical active microwave temperature imaging: numerical simulationsIEEE Transactions on Medical Imaging, 1992
- Inverse scattering: an iterative numerical method for electromagnetic imagingIEEE Transactions on Antennas and Propagation, 1991
- Medical imaging with a microwave tomographic scannerIEEE Transactions on Biomedical Engineering, 1990
- Three-dimensional finite, boundary, and hybrid element solutions of the Maxwell equations for lossy dielectric mediaIEEE Transactions on Microwave Theory and Techniques, 1988
- Hybrid element method for unbounded electromagnetic problems in hyperthermiaInternational Journal for Numerical Methods in Engineering, 1986
- In Situ Permittivity of Canine Brain: Regional Variations and Postmortem ChangesIEEE Transactions on Microwave Theory and Techniques, 1986
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978