Determination of Halogenated Hydrocarbons by Helium Microwave Plasma Torch Time-of-Flight Mass Spectrometry Coupled to Gas Chromatography
- 5 August 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (18) , 3957-3963
- https://doi.org/10.1021/ac970534r
Abstract
A helium microwave plasma torch (MPT) was coupled to time-of-flight mass spectrometry (TOFMS) for the detection of halogenated hydrocarbons separated by capillary gas chromatography (GC). The GC-MPT-TOFMS system offered excellent stability over the course of the experiments and avoided mass spectral peak distortions caused by spectral skew. In the initial studies, empirical formulas based on the halogen-to-carbon ratio were predicted utilizing a flow cell apparatus. The MPT proved to be very robust and could handle large amounts of organic vapor. Results from this study indicate that, for both aromatic and aliphatic halogenated hydrocarbons, the ratios of carbon to chlorine signals correlate well (r = 0.994) with the ones expected from their chemical composition. This study was later extended to include chromatographic separation. For a series of homologous aliphatic halogenated hydrocarbons, a correlation coefficient of 0.999 was obtained for both peak heights and peak areas obtained from a single chromatogram. A novel Nichrome wire-heated transfer line was developed to ensure that the capillary column was heated efficiently from the GC oven to the MPT and then through the length of the MPT up to the microwave plasma itself. No appreciable peak broadening and no detectable memory effects were associated with the heated transfer line. The GC-MPT-TOFMS system offered equal sensitivity for I, Br, and Cl. Absolute detection limits for the halogenated hydrocarbons ranged from 160 to 330 fg, constituting an improvement by a factor of 5−35 over earlier results obtained with MIPs supported in a TM010 cavity and combined with quadrupole-based mass spectrometry. In addition, the effect of molecular gases on the MPT performance was investigated. Up to about 1% (v/v) of either oxygen or hydrogen in the central channel helium flow attenuated the signal levels for both carbon and chlorine, with the larger loss seen in the chlorine signal.Keywords
This publication has 20 references indexed in Scilit:
- An inductively coupled plasma-time-of-flight mass spectrometer for elemental analysis. Part I: Optimization and characteristicsJournal of the American Society for Mass Spectrometry, 1994
- Direct coupling of continuous hydride generation with microwave plasma torch atomic emission spectrometry for the determination of arsenic, antimony and tinSpectrochimica Acta Part B: Atomic Spectroscopy, 1994
- Evaluation of flow-injection techniques for microwave plasma torch atomic emission spectrometryAnalytica Chimica Acta, 1993
- Recent advances in speciation analysis by capillary gas chromatography—microwave induced plasma atomic emission spectrometryTrAC Trends in Analytical Chemistry, 1993
- Element-Specific Chromatographic Detection by Atomic Emission SpectroscopyPublished by American Chemical Society (ACS) ,1992
- Sensitive speciation analysis of lead ion environmental waters by capillary gas chromatography microwave-induced plasma atomic emission spectrometryAnalytica Chimica Acta, 1992
- Determination of halogenated organic compounds by electrothermal vaporization into a helium microwave induced plasma at atmospheric pressureAnalytica Chimica Acta, 1982
- Elemental analysis with a microwave-induced plasma/quadrupole mass spectrometer systemAnalytical Chemistry, 1981
- Selective emission spectrometric determination of nanogram quantities of organic bromine, chlorine, iodine, phosphorus, and sulfur compounds in a helium plasmaAnalytical Chemistry, 1967
- Sensitive Selective Gas Chromatography Detector Based on Emission Spectrometry of Organic Compounds.Analytical Chemistry, 1965