Prediction of long‐term polyethylene wear in total hip arthroplasty, based on early wear measurements made using digital image analysis
- 1 September 1998
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 16 (5) , 557-563
- https://doi.org/10.1002/jor.1100160506
Abstract
The capability to reliably predict long-term in vivo wear of polyethylene would be of great value for the early identification of problematic total hip designs. Formal quantitative estimates of long-term polyethylene wear were made from a series of 197 patients who had a total hip arthroplasty and who were followed for a minimum of 10 years; the estimates were based on the wear that was apparent radiographically at nominally 2 years after the operation. A newly developed digital image-analysis edge-detection procedure was applied to 1,237 archived follow-up radiographs. The edge-detection measurements were analyzed with a robust regression random-coefficients statistical formulation developed especially to address the distributions of wear rate observed across this population over time. Formal regression equations were reported, which can be used to estimate late-wear depth for a patient radiographed at a 2-year follow-up visit. Series wide, the correlation between predicted and observed wear depths was 0.73 at 4 years, with a correlation decline of approximately 0.03 per additional year.Keywords
This publication has 24 references indexed in Scilit:
- Contribution of Cable Debris Generation to Accelerated Polyethylene WearClinical Orthopaedics and Related Research, 1997
- Digital Edge-Detection Measurement of Polyethylene Wear after Total Hip Arthroplasty*Journal of Bone and Joint Surgery, 1997
- Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implantThe Journal of Arthroplasty, 1996
- Adaptiive finite element modeling of long‐term polyethylene wear in total hip arthroplastyJournal of Orthopaedic Research, 1996
- Early failure of hylamer acetabular inserts due to eccentric wearThe Journal of Arthroplasty, 1996
- Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.Journal of Bone and Joint Surgery, 1992
- Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads.Journal of Bone and Joint Surgery, 1989
- Size of the femoral head and acetabular revision in total hip-replacement arthroplasty.Journal of Bone and Joint Surgery, 1989
- The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.Journal of Bone and Joint Surgery, 1986
- Rate of Wear in Total Hip ReplacementClinical Orthopaedics and Related Research, 1975