Mechanical ventilation with lower tidal volumes does not influence the prescription of opioids or sedatives
Open Access
- 13 July 2007
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 11 (4) , R77
- https://doi.org/10.1186/cc5969
Abstract
Introduction: We compared the effects of mechanical ventilation with a lower tidal volume (VT) strategy versus those of greater VT in patients with or without acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) on the use of opioids and sedatives. Methods: This is a secondary analysis of a previously conducted before/after intervention study, which consisting of feedback and education on lung protective mechanical ventilation using lower VT. We evaluated the effects of this intervention on medication prescriptions from days 0 to 28 after admission to our multidisciplinary intensive care unit. Results: Medication prescriptions in 23 patients before and 38 patients after intervention were studied. Of these patients, 10 (44%) and 15 (40%) suffered from ALI/ARDS. The VT of ALI/ARDS patients declined from 9.7 ml/kg predicted body weight (PBW) before to 7.8 ml/kg PBW after the intervention (P = 0.007). For patients who did not have ALI/ARDS there was a trend toward a decline from 10.2 ml/kg PBW to 8.6 ml/kg PBW (P = 0.073). Arterial carbon dioxide tension was significantly greater after the intervention in ALI/ARDS patients. Neither the proportion of patients receiving opioids or sedatives, or prescriptions at individual time points differed between pre-intervention and post-intervention. Also, there were no statistically significant differences in doses of sedatives and opioids. Findings were no different between non-ALI/ARDS patients and ALI/ARDS patients. Conclusion: Concerns regarding sedation requirements with use of lower VT are unfounded and should not preclude its use in patients with ALI/ARDS.Keywords
This publication has 24 references indexed in Scilit:
- What Tidal Volumes Should Be Used in Patients without Acute Lung Injury?Anesthesiology, 2007
- The reliability and validity of a new and simple method to measure sedation levels in intensive care patients: A pilot studyHeart & Lung, 2006
- Low tidal volume ventilation does not increase sedation use in patients with acute lung injury*Critical Care Medicine, 2005
- Acute effects of tidal volume strategy on hemodynamics, fluid balance, and sedation in acute lung injury*Critical Care Medicine, 2005
- Why are physicians so skeptical about positive randomized controlled clinical trials in critical care medicine?Intensive Care Medicine, 2004
- Higher versus Lower Positive End-Expiratory Pressures in Patients with the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2004
- Barriers to providing lung-protective ventilation to patients with acute lung injuryCritical Care Medicine, 2004
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- Current definitions of acute lung injury and the acute respiratory distress syndrome do not reflect their true severity and outcome.Intensive Care Medicine, 1999
- The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination.American Journal of Respiratory and Critical Care Medicine, 1994