Interface for Direct and Continuous Sample−Matrix Deposition onto a MALDI Probe for Polymer Analysis by Thermal Field Flow Fractionation and Off-Line MALDI-MS
- 5 April 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (9) , 3008-3012
- https://doi.org/10.1021/ac048391d
Abstract
A simple interface based on an oscillating capillary nebulizer (OCN) is described for direct deposition of eluate from a thermal field-flow fractionation (ThFFF) system onto a matrix-assisted laser desorption/ionization (MALDI) probe. In this study, the polymer-containing eluent from the ThFFF system was mixed on-line with MALDI matrix solution and deposited directly onto a moving MALDI probe. The result was a continuous sample track representative of the fractionation process. Subsequent off-line MALDI-mass spectrometry analysis was performed in automated and manual modes. Polystyrene samples of broad polydispersity were used to characterize the overall system performance. The OCN interface is easy to build and operate without the use of heaters or high voltages and is compatible with any MALDI probe format.Keywords
This publication has 19 references indexed in Scilit:
- Online CE−MALDI-TOF MS Using a Rotating Ball InterfaceAnalytical Chemistry, 2004
- On-line atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometryThe Analyst, 2004
- A Modified Thermal Deposition Unit for Gel-Permeation Chromatography with Matrix-Assisted Laser Desorption/Ionization and Electrospray Ionization Time-of-Flight AnalysisEuropean Journal of Mass Spectrometry, 2002
- Interfaces for coupled liquid‐phase separation/mass spectrometry techniques. An update on recent developmentsJournal of Mass Spectrometry, 2002
- Full copolymer characterization by SEC–NMR combined with SEC–MALDIPolymer, 2001
- GPC Separation of Polymer Samples for MALDI AnalysisAnalytical Chemistry, 2000
- Matrix-assisted laser desorption/ionization mass spectrometry of synthetic polymers. 4. Coupling of size exclusion chromatography and MALDI-TOF using a spray-deposition interfacePolymer, 2000
- Mass Discrimination Effects in an Ion Detector and Other Causes for Shifts in Polymer Mass Distributions Measured by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass SpectrometryMacromolecules, 1996
- Comparison of polymer resolution in thermal field-flow fractionation and size-exclusion chromatographyAnalytica Chimica Acta, 1986
- Chemical composition and molecular-size factors in polymer analysis by thermal field-flow fractionation and size exclusion chromatographyMacromolecules, 1986