Heparin-coated cardiopulmonary bypass circuits: current status
- 1 September 2001
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 16 (5) , 417-428
- https://doi.org/10.1177/026765910101600512
Abstract
Heparin-coated circuits have been subjected to vigorous testing, both experimentally and clinically, for the past decade. When the functions of heparin are preserved on the surface, the heparinized surface plays multiple roles in attenuating the systemic inflammatory response. These include the ability to attenuate contact activation, coagulation activation, complement activation and, directly or indirectly, platelet and leukocyte activation. The heparinized surface also renders the cardiopulmonary bypass (CPB) circuits hydrophilic and protein resistant and augments lipoprotein binding. The multifunctional nature of the heparinized surface contributes to the overall biocompatibility of the surface. Clinically, heparin-coated circuits become most effective in reducing systemic inflammatory response and in improving morbidity, mortality, and other patient outcome related parameters when material-independent blood activation is controlled or minimized through a global biocompatibility strategy. Techniques involved in the global biocompatibility strategy are readily available and are being effectively and safely practiced at several centers. With the global biocompatibility strategy, outstanding and reproducible results have been routinely achieved with conventional CPB techniques. Alternative revascularization procedures should equal or surpass conventional CPB, using best clinically proven strategies with respect to patient outcome and long-term graft patency.Keywords
This publication has 64 references indexed in Scilit:
- Particulate emboli capture by an intra-aortic filter device during cardiac surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Heparin-coated Cardiopulmonary Bypass Circuits Reduce Circulating Complement Factors and Interleukin-6 in Paediatric Heart SurgeryScandinavian Cardiovascular Journal, 2000
- Heparin-coated cardiopulmonary bypass equipment. II. Mechanisms for reduced complement activation in vivoThe Journal of Thoracic and Cardiovascular Surgery, 1999
- HELP Apheresis in the Treatment of SepsisArtificial Organs, 1998
- Influence of Two Blood Conservation Techniques (Cardiotomy Reservoir Versus Cell-Saver) on Biocompatibility of the Heparin Coated Cardiopulmonary Bypass Circuit During Coronary Revascularization SurgeryJournal of Cardiac Surgery, 1997
- Low Heparinization With Heparin-Bonded Bypass Circuits: Is It a Safe Strategy?The Annals of Thoracic Surgery, 1997
- The effects of carmeda bioactive surface on human blood components during simulated extracorporeal circulationThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Heparin‐coated circuits reduce the formation of TNFα during cardiopulmonary bypassActa Anaesthesiologica Scandinavica, 1996
- Heparin binding to human plasma low-density lipoproteins: dependence on heparin sulfation degree and chain lengthBiochemistry, 1992
- Clinical experience with heparin-coated cardiopulmonary bypass circuitsPerfusion, 1991