COMPARATIVE EVALUATION OF UROGRAPHIC CONTRAST MEDIA, INULIN, AND 99mTc-DTPA CLEARANCE METHODS FOR DETERMINATION OF GLOMERULAR FILTRATION RATE IN CLINICAL TRANSPLANTATION
- 1 November 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Transplantation
- Vol. 48 (5) , 790-795
- https://doi.org/10.1097/00007890-198911000-00013
Abstract
Plasma clearances of inulin (Cin), 99mTc-DTPA (CDTPA), and urographic contrast media (CCM) were determined simultaneously in 31 patients with varying levels of renal function evaluated in the setting of affiliated cardiac and renal transplantation programs. Cin and CDTPAwere calculated from the ratio of simutaneously measured plasma concentration and urine excretion rate of these test agents (U.RTM.V/P). CCM was derived from x-ray fluorescence measurement of plasma iodine (PI) content following intravenous injection of 50 ml of nonionic, low-osmolar contrast media (180 mg I/ml). Urine collections were not required for CCM determinations. No adverse reactions attributable to CM occurred in any patient, and follow-up serum-creatinine values did not differ significantly from prestudy levels. CCM determined from the rate of decline in PI between 3 hr and 4 hr following administration of contrast media ("slope-intercept" technique) [Ccm-SI] correlated closely with corresponding levels of Cin (r = .86, P < 0.0001), and CDTPA (r = 0.89, 0.0001). Mean CCM-SI/Cin and CCM-SI/CDTPA ratios for the entire study cohort were 1.09 .+-. 0.06 and 1.08 .+-. 0.06, respectively. CCM-SI determinations also correlated well with CCM levels derived from a single measurement of PI ("single sample" technique) made at 3 hr following injection of contrast media (R = 0.94, P < 0.0001). Both CCM-SI and CCM determined by the "single sample" method (CCM-3.degree.SS) tended to overestimate Cin and CDTPA, however, when the latter were < 20 ml/min/1.73 m2 (mean CCM-SI/Cin and Ccm-3.degree.SS/Cin ratios 1.36 .+-. 0.14 and 1.95 .+-. 1.0), respectively. Reproducibility was evaluated by paired comparison of 3-hr vs. 4-hr "single sample" CCM determinations (r = 0.99, P < 0.0001). In addition, analysis of the variation in iodine content between duplicate specimens obtained at each of these time intervals revealed a mean ratio of 1.0 .+-. 0.01 (P = NS vs. identity). Contrast clearance determination utilizing the slope-intercept method is accurate, safe, pragmatic, and more precise than serum-creatinine and endogenous-creatinine clearance for measurement of renal function in clinical transplantation.This publication has 19 references indexed in Scilit:
- Limitations of creatinine as a filtration marker in glomerulopathic patientsKidney International, 1985
- Renal Function following Nephroangiography with Metrizamide and IohexolActa Radiologica. Diagnosis, 1985
- High Dose Urography in Patients with Renal FailureActa Radiologica. Diagnosis, 1985
- Renal Function following Nephroangiography with DiatrizoateActa Radiologica. Diagnosis, 1984
- PLASMA-CLEARANCE OF A NEW CONTRAST AGENT, IOHEXOL - A METHOD FOR THE ASSESSMENT OF GLOMERULAR-FILTRATION RATE1984
- QUALITY-CONTROL OF TC-99M DTPA FOR MEASUREMENT OF GLOMERULAR-FILTRATION - CONCISE COMMUNICATION1983
- Creatinine: An inadequate filtration marker in glomerular diseasesThe American Journal of Medicine, 1980
- The Usefulness of125I-sodium lothalamate as a GFR-indicator in Single Intravenous Injection TestsUpsala Journal of Medical Sciences, 1978
- Plasmatic diatrizoate-I131 disappearance and glomerular filtration in the dogAmerican Journal of Physiology-Legacy Content, 1963