The 15O Steady-State Method: Correction for Variation in Arterial Concentration
- 1 October 1988
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 8 (5) , 681-690
- https://doi.org/10.1038/jcbfm.1988.115
Abstract
One of the factors limiting the accuracy of the 15O steady-state method for the measurement of regional cerebral blood flow and oxygen metabolism is the requirement that a constant arterial blood concentration be maintained over long periods. A new method has been developed to correct for the variation of the arterial concentration in the C15O2 and 15O2 steady-state inhalation technique. The time course of the arterial activity is obtained by multiple sampling over the study period. The same 15O model as is used in the steady-state method is employed but is solved without assuming equilibrium. Look-up tables are generated to relate flow and oxygen extraction fraction to tissue activity, and from them the regional parameters are estimated. Theory and simulation studies suggest that substantial improvement in accuracy can be obtained with no increase in statistical error. The validity of the method was checked experimentally by making repeated measurements in the same subject after perturbing the gas delivery. The conventional steady-state method showed significantly larger deviations in repeat measurement than did the new method. Thus, it is concluded that the proposed method is superior.Keywords
This publication has 16 references indexed in Scilit:
- Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input FunctionJournal of Cerebral Blood Flow & Metabolism, 1986
- Analysis of Some Errors in the Measurement of Oxygen Extraction and Oxygen Consumption by the Equilibrium Inhalation MethodJournal of Cerebral Blood Flow & Metabolism, 1985
- Performance Study of the PC-384 Positron Camera System for Emission Tomography of the BrainJournal of Computer Assisted Tomography, 1984
- Effect of Tissue Heterogeneity on the Measurement of Cerebral Blood Flow with the Equilibrium C15O2 Inhalation TechniqueJournal of Cerebral Blood Flow & Metabolism, 1983
- SERIAL OBSERVATIONS ON THE PATHOPHYSIOLOGY OF ACUTE STROKEBrain, 1983
- Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission TomographyJournal of Computer Assisted Tomography, 1982
- Error Analysis for the Determination of Cerebral Blood Flow with the Continuous Inhalation of 15O-Labeled Carbon Dioxide and Positron Emission TomographyJournal of Computer Assisted Tomography, 1982
- Reversal of focal "misery-perfusion syndrome" by extra-intracranial arterial bypass in hemodynamic cerebral ischemia. A case study with 15O positron emission tomography.Stroke, 1981
- A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopesPhysics in Medicine & Biology, 1979
- The continuous inhalation of Oxygen-15 for assessing regional oxygen extraction in the brain of manThe British Journal of Radiology, 1976