Implantable transducer for two-degree of freedom joint angle sensing
- 1 September 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Rehabilitation Engineering
- Vol. 7 (3) , 349-359
- https://doi.org/10.1109/86.788471
Abstract
An implantable joint angle transducer (IJAT) was developed to provide command-control and feedback-control information for chronic use with functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses Hall effect sensors to transduce joint angle. A titanium encapsulated array of Hall effect sensors and support circuitry is surgically implanted in one bone, and a similarly encapsulated permanent magnet in an opposing bone, across a joint. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from midsized two-degree-of-freedom joints. IJATs were implanted using a chronic in vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate modeling techniques used for prediction of function and calibration. The flexion resolution ranged from 0.4 to 3.0/spl deg/ over a range of 115/spl deg/. The maximum deviation from a linear response was 9/spl deg/. The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted prior to implantation and calibrated after implantation. The results of this study (1) defined the most appropriate hermetic capsule designs for the IJAT sensor and magnet, (2) defined the best orientation of the magnetic field to optimize device function, (3) provided a computer model of the IJAT to aid in placement, calibration, and evaluation of the device, (4) verified the surgical techniques used to implant the device, and (5) verified the long-term functionality and the biocompatibility of the device.Keywords
This publication has 23 references indexed in Scilit:
- An implantable transducer for two-degree-of-freedom joint angle sensingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*Journal of Bone and Joint Surgery, 1997
- Instrumented assessment of FNS hand control during specific manipulation tasksIEEE Transactions on Rehabilitation Engineering, 1994
- Evaluation of shoulder movement as a command control sourceIEEE Transactions on Biomedical Engineering, 1990
- Implantable functional neuromuscular stimulation in the tetraplegic handThe Journal of Hand Surgery, 1989
- Functional Neuromuscular Stimulation Neuroprostheses for the Tetraplegic HandPublished by Wolters Kluwer Health ,1988
- Functional electrical stimulation: current status and future prospects of applications to the neuromuscular system in spinal cord injurySpinal Cord, 1987
- The Packaging of Implantable Integrated SensorsIEEE Transactions on Biomedical Engineering, 1986
- Packaging Materials and Techniques for Implantable InstrumentsIEEE Engineering in Medicine and Biology Magazine, 1983
- Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculatureAnnals of Biomedical Engineering, 1980