To assess the diagnostic performance of an active-matrix flat-panel x-ray detector for reduced-dose imaging of simulated arthritic lesions. A digital x-ray detector based on cesium iodide and amorphous silicon technology with a panel size of 43 x 43 cm, matrix of 3,000 x 3,000 pixels, pixel size of 143 micrometer, and digital output of 14 bits was used. State-of-the-art screen-film radiographs were compared with digital images obtained at doses equivalent to those obtained with system speeds of 400, 560, and 800. The phantom was composed of a human hand skeleton on an acrylic plate with drilled holes simulating bone erosions of different diameters and depths. Results of four independent observers were evaluated with receiver operating characteristic curve analysis. The cesium iodide and amorphous silicon detector resulted in better diagnostic performance than did the screen-film combination, with the dose being the same for both modalities (P <.05). For digital images obtained at reduced doses, no significant differences were found. The improved diagnostic performance with digital radiographs obtained with the cesium iodide and amorphous silicon detector suggests that this detector technology holds promise in terms of dose reduction for specific diagnostic tasks, without loss of diagnostic accuracy.Keywords
This publication has 8 references indexed in Scilit:
- Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography.American Journal of Roentgenology, 1998
- Detection of Simulated Chest Lesions with Normal and Reduced Radiation DoseInvestigative Radiology, 1998
- Amorphous Silicon, Flat-Panel, X-Ray Detector Versus Screen-Film RadiographyInvestigative Radiology, 1998
- Flat-Panel X-Ray Detector Using Amorphous Silicon TechnologyInvestigative Radiology, 1997
- The AAPM/RSNA physics tutorial for residents. Measures of screen-film performance.RadioGraphics, 1996
- Artificial bone erosions: detection with magnification radiography versus conventional high-resolution radiography.Radiology, 1994
- Morphologische Analyse der Wirbelkörperspongiosa in der quantitativen CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1992