The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints
- 1 February 2001
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 215 (2) , 259-263
- https://doi.org/10.1243/0954411011533661
Abstract
There is considerable interest in the wear of polyethylene and the resulting wear-debrisinduced osteolysis in artificial hip joints. Proteins play an important role as boundary lubricants in vivo in the pseudosynovial fluid, and these are reproduced in in vitro tests through the use of bovine serum. Little is known, however, about the effect of phospholipid concentrations within proteinaceous solutions on the wear of ultra-high molecular weight polyethylene (UHMWPE). The effects of protein-containing lubricants with 0.05, 0.5 and 5 per cent (w/v) phosphatidyl choline concentrations on the wear of ultra-high molecular weight polyethylene (UHMWPE) were compared with 25 per cent (v/v) bovine serum which had 0.01 per cent (w/v) lipid; the effects were compared in a hip joint simulator with smooth (n = 4) and scratched (n = 3) femoral heads. The control bovine serum lubricant produced UHWMPE wear of 55 and 115mm3/106 cycles on the smooth and rough heads respectively. The increased phospholipid concentration significantly reduced the wear rate. At the higher concentration (5% w/v phosphatidyl choline) the average wear was reduced to less than 2 mm3/106 cycles. Even with the relatively low concentrations of 0.05% w/v phosphatidyl choline the wear was reduced by at least threefold compared with the bovine serum tests for both the smooth and rough femoral heads. There may be considerable differences in the phospholipid concentrations in patients' synovial fluid and this is highly likely to produce considerable variation in wear rates. In vitro, differences in the phospholipid concentration of lubricants may also cause variation in wear rates between different simulator tests.Keywords
This publication has 15 references indexed in Scilit:
- A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cupsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulationsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Biological reactions to wear debris in total joint replacementProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prosthesesJournal of Materials Science: Materials in Medicine, 2000
- Boundary lubrication in vivoProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethyleneThe Journal of Bone and Joint Surgery. British volume, 1999
- The lubricating ability of biomembrane models with dipalmitoyl phosphatidylcholine and γ-globulinProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1998
- Wear of prosthetic joint materials in various lubricantsWear, 1997
- Tissue Reaction to Metal on Metal Total Hip ProsthesesClinical Orthopaedics and Related Research, 1996
- Surfactants identified in synovial fluid and their ability to act as boundary lubricants.Annals of the Rheumatic Diseases, 1984