Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations
- 1 May 2000
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 214 (5) , 513-518
- https://doi.org/10.1243/0954411001535543
Abstract
Ultra-high molecular weight polyethylene (UHMWPE) wear debris induced osteolysis has a major role in the late aseptic loosening and ultimate failure of total hip replacements (THR). Clinically relevant in vitro simulations of wear are essential to predict the osteolytic potential of bearing surfaces in artificial hip joints. Newborn calf or bovine serum has been accepted as a boundary lubricant for such in vitro tests, but its biological stability has been questioned. This study compared the wear factors, number of wear particles and levels of microbial contamination produced in bovine serum and a gelatin-based lubricant. The wear factors produced by the two lubricants were not significantly different, however the wear debris morphology produced was substantially different. The bovine serum became contaminated with micro-organisms within 28 h, whereas the protein-based lubricant remained uncontaminated. The results showed that bovine serum was not a stable boundary lubricant. They also showed that although the wear factors for the two solutions were not significantly different, the protein-based lubricant was not a suitable alternative to bovine serum because the wear debris produced was not clinically relevant.Keywords
This publication has 13 references indexed in Scilit:
- Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prosthesesJournal of Materials Science: Materials in Medicine, 2000
- A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and ratesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory testsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- The lubricating ability of biomembrane models with dipalmitoyl phosphatidylcholine and γ-globulinProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1998
- Wear of prosthetic joint materials in various lubricantsWear, 1997
- Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricantProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Cytokines in aseptic loosening of total hip replacementCurrent Orthopaedics, 1997
- Macrophage/particle interactions: Effect of size, composition and surface areaJournal of Biomedical Materials Research, 1994
- Composition and morphology of wear debris in failed uncemented total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1994
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977