Atrial Response to Ventricular Antitachycardia Pacing Discriminates Mechanism of 1:1 Atrioventricular Tachycardia
- 12 April 2005
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (6) , 601-605
- https://doi.org/10.1046/j.1540-8167.2005.40474.x
Abstract
Inappropriate shocks from implantable cardioverter defibrillators (ICD) remain a significant clinical problem despite device discrimination algorithms. The atrial response to antitachycardia pacing (ATP) may determine the mechanism of 1:1 A:V tachycardia. For this study we refer to sinus tachycardia, atrial tachycardia (AT), atrial fibrillation, and flutter as atrial tachycardia (AT), and all other tachycardia as "non-AT." Three atrial response patterns during the burst of ATP were determined. The atrial cycle length (ACL) may be unchanged (type 1) indicating AT. The ACL may show variation during ATP (type 2) indicating variable VA block and does not discriminate between an AT and a non-AT mechanism, in which case a default diagnosis of non-AT is made. The ACL may accelerate to the ATP cycle length (type 3) indicating entrainment. A VAAV response at the end of ATP was considered diagnostic of AT (type 3A) whereas a VAV or VVA response was considered a non-AT mechanism (type 3B). This algorithm was applied to ICD tracings from 68 episodes of spontaneous 1:1 A:V tachycardia that had 136 sequences of ATP administered. The rhythm "truth" was determined by consensus of two experienced clinicians. The algorithm correctly identified AT with a sensitivity of 71.9% (95% CI: 67.1-73.6), and specificity of 95% (83.5-99.1). The PPV was 97.2% (90.9-99.5), and NPV 58.5% (51.4-61.0). Kappa was 0.57 (0.43-0.62). If used clinically the algorithm would have aborted 53.3% (8/15) of inappropriate shocks delivered into an AT-mechanism tachycardia and would not have withheld a shock for any episode of VT. Analysis of atrial response patterns during and after ventricular ATP can successfully discriminate tachycardia mechanism and may reduce inappropriate ICD shocks.Keywords
This publication has 14 references indexed in Scilit:
- Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia.EP Europace, 2004
- Implantable Cardioverter Defibrillator Events in Patients with Asymptomatic Nonsustained Ventricular Tachycardia:Pacing and Clinical Electrophysiology, 2003
- Safety and Efficacy of a Dual Chamber Implantable Cardioverter Defibrillator Capable of Slow Ventricular Tachycardia Discrimination:Pacing and Clinical Electrophysiology, 2003
- Analysis of Implantable Cardioverter Defibrillator Therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) TrialJournal of Cardiovascular Electrophysiology, 2003
- An Adaptive Interval‐Based Algorithm for Withholding ICD Therapy During Sinus TachycardiaPacing and Clinical Electrophysiology, 2003
- Clinical Investigation of a New Dual‐Chamber Implantable Cardioverter Defibrillator with Improved Rhythm Discrimination CapabilitiesJournal of Cardiovascular Electrophysiology, 2003
- Shock Reduction Using Antitachycardia Pacing for Spontaneous Rapid Ventricular Tachycardia in Patients With Coronary Artery DiseaseCirculation, 2001
- Inappropriate Detection of Supraventricular Arrhythmias by Implantable Dual Chamber Defibrillators: A Comparison of Four Different AlgorithmsPacing and Clinical Electrophysiology, 2001
- Critical Analysis of Dual-Chamber Implantable Cardioverter-Defibrillator Arrhythmia DetectionCirculation, 2001
- Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter DefibrillatorsCirculation, 1998