Effect of Isthmus Anatomy and Ablation Catheter on Radiofrequency Catheter Ablation of the Cavotricuspid Isthmus
- 31 August 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 110 (9) , 1030-1035
- https://doi.org/10.1161/01.cir.0000139845.40818.75
Abstract
Background— Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to treat (with a long CTI, >35 mm). Methods and Results— Over a period of 17 months, 185 patients accepted the protocol and underwent an isthmogram in preparation for RFA. Groups were classified according to CTI length and CTI morphology. RFA was performed with an 8-mm-tip catheter for patients with a short CTI, ≤35 mm (n=123), whereas randomization between an 8-mm-tip and a cooled-tip catheter applied to patients with a longer CTI, >35 mm (n=62). For long CTI, 32 patients were assigned to an 8-mm catheter and 30 patients to the cooled-tip RFA ablation group. In this subset, RF application (18.2±17 versus 19±13 minutes) and x-ray exposure (20.8±18 versus 18±13 minutes) did not differ between the 8-mm-tip and the cooled-tip procedures. Number of applications (9.9±11 versus 18.6±15 minutes; P P =0.0001) differed significantly between patients with short and long CTIs. Patients with short and straight CTIs required 3 times fewer RFA applications and shorter x-ray exposure compared with other CTI morphologies (pouch-like recesses and concave characteristics). Conclusions— The number of RF applications required for a complete isthmus block in long CTIs is not influenced by the choice between an 8-mm or cooled-tip catheter. Procedure parameters, however, are significantly influenced by CTI length and morphology. Pouch-like recesses and concave characteristics account for much longer ablation times at all CTI lengths.Keywords
This publication has 10 references indexed in Scilit:
- Phased‐Array Intracardiac Echocardiography for Defining Cavotricuspid Isthmus Anatomy During Radiofrequency Ablation of Typical Atrial FlutterJournal of Cardiovascular Electrophysiology, 2003
- Is a Cooled Tip Catheter the Solution for the Ablation of the Cavotricuspid Isthmus?Pacing and Clinical Electrophysiology, 2003
- Prospective Randomized Comparison of Closed Cooled‐Tip versus 8‐mm‐Tip Catheters for Radiofrequency Ablation of Typical Atrial FlutterJournal of Cardiovascular Electrophysiology, 2002
- Effectiveness of irrigated tip catheter ablation of common atrial flutterThe American Journal of Cardiology, 2001
- Impact of Biventricular Pacing on Mortality in a Randomized Crossover Study of Patients with Heart Failure and Ventricular ArrhythmiasPacing and Clinical Electrophysiology, 2000
- Prospective randomized comparison of antiarrhythmic therapy versus first-line radiofrequency ablation in patients with atrial flutterPublished by Elsevier ,2000
- Comparison of results of an 8-mm split-tip versus a 4-mm tip ablation catheter to perform radiofrequency ablation of type I atrial flutterThe American Journal of Cardiology, 2000
- Local Electrogram‐Based Criteria of Cavotricuspid Isthmus BlockJournal of Cardiovascular Electrophysiology, 1999
- The Architecture of the Atrial Musculature Between the Orifice of the Inferior Caval Vein and the Tricuspid Valve: The Anatomy of the IsthmusJournal of Cardiovascular Electrophysiology, 1998
- Why a Large Tip Electrode Makes a Deeper Radiofrequency Lesion:Journal of Cardiovascular Electrophysiology, 1998