Ineffectiveness of Hospital Disinfectants Against Bacteria: A Collaborative Study
- 1 August 1987
- journal article
- research article
- Published by Cambridge University Press (CUP) in Infection Control
- Vol. 8 (12) , 501-506
- https://doi.org/10.1017/s0195941700067564
Abstract
A collaborative study was undertaken to assess the degree of variability in disinfectant efficacy test results among laboratories that routinely perform the Association of Official Analytical Chemists (AOAC) Use-Dilution Method. Eighteen laboratories tested identical samples of six EPA-registered, hospital-grade disinfectants (three phenolics and three quaternaries) at the manufacturers' recommended use-dilution using only those modifications of the method approved by the AOAC Use-Dilution Task Force. Each laboratory processed 60 penicylinders for each of the 6 randomly selected disinfectants and 3 test organisms. The current EPA pass criterion for a disinfectant requires a test result of ≤1 positive penicyIinder/60 replicates tested. When compared with the 1 positive/60 replicate criterion, the test results of the 6 disinfectants were: 86 trials (80%) passed and 22 trials (20%) failed against Salmonella choleraesuis ATCC 10708; 71 (66%) passed and 37 (34%) failed against Staphylococcus aureus ATCC 6538; and 41 (38%) passed while 67 (62%) failed against Pseudomonas aeruginosa ATCC 15442. Four laboratories unknowingly tested their own product, and three of the four failed their product against one or more of the test organisms. These results show the inability to reproduce the manufacturers' bactericidal label claims for 6 disinfectants against the 3 AOAC test bacteria. In addition, extreme variability of test results among laboratories testing identical products questions the use of the AOAC Use-Dilution Method for enforcement action.This publication has 11 references indexed in Scilit:
- Evaluation of Penicylinders Used in Disinfectant Testing: Bacterial Attachment and Surface TextureJournal of AOAC INTERNATIONAL, 1987
- Drug-Resistant Salmonella from Animals Fed AntimicrobialsNew England Journal of Medicine, 1984
- Relation of the Inanimate Hospital Environment to Endemic Nosocomial InfectionNew England Journal of Medicine, 1982
- ANTIBIOTIC-SENSITIVE SERRATIA MARCESCENS INFECTIONS COMPLICATING CARDIOPULMONARY OPERATIONS: CONTAMINATED DISINFECTANT AS A RESERVOIRThe Lancet, 1980
- Fiberoptic Bronchoscope-Related Outbreak of Infection with PseudomonasChest, 1978
- Aqueous Quaternary Ammonium Antiseptics and DisinfectantsPublished by American Medical Association (AMA) ,1976
- Aqueous quaternary ammonium antiseptics and disinfectants. Use and misuseJAMA, 1976
- Outbreak of Serratia Marcescens Associated with the Flexible FiberbronchoscopeChest, 1975
- Bacteremia Following Cardiac CatheterizationNew England Journal of Medicine, 1959