The Variability of Femoral Rotational Alignment in Total Knee Arthroplasty
- 1 October 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (10) , 2276-2280
- https://doi.org/10.2106/jbjs.d.02945
Abstract
Background: Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if navigation systems can improve the accuracy of femoral rotational alignment as compared with that achieved with more traditional techniques involving mechanical guides. The purposes of the present study were to characterize the variability associated with femoral rotational alignment techniques and to determine whether the use of a computer-assisted surgical navigation system reduced this variability. Methods: Eleven orthopaedic surgeons used five alignment techniques (including one computer-assisted technique and four traditional techniques) to establish femoral rotational alignment axes on ten cadaveric specimens, and the orientation of these axes was recorded with use of a navigation system. These derived axes were compared against a reference transepicondylar axis on each femur that was established after complete dissection of all soft tissues. Results: There was no difference between the mean errors of all five techniques (p > 0.11). Only 17% of the knees were rotated Conclusions: All techniques resulted in highly variable rotational alignment, with no technique being superior. This variability was primarily due to the particular surgeon who was performing the alignment procedure. A navigation system that relies on directly digitizing the femoral epicondyles to establish an alignment axis did not provide a more reliable means of establishing femoral rotational alignment than traditional techniques did.Keywords
This publication has 13 references indexed in Scilit:
- Navigation Improves Accuracy of Rotational Alignment in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2004
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacementActa Orthopaedica, 2004
- How Accurate is Current TKR Instrumentation?Clinical Orthopaedics and Related Research, 2003
- Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axisKnee Surgery, Sports Traumatology, Arthroscopy, 2002
- Optimizing Femoral Component Rotation in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2001
- The Transepicondylar Axis Approximates the Optimal Flexion Axis of the KneeClinical Orthopaedics and Related Research, 1998
- Malrotation Causing Patellofemoral Complications After Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- Computer Assisted Knee ReplacementClinical Orthopaedics and Related Research, 1998
- Rotational Landmarks and Sizing of the Distal Femur in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996