Depth resolution improvements using specimen rotation during depth profiling
- 1 January 1989
- journal article
- research article
- Published by Wiley in Surface and Interface Analysis
- Vol. 14 (1-2) , 95-98
- https://doi.org/10.1002/sia.740140119
Abstract
It has been well documented that depth resolution (interface width) degrades with depth when crystalline materials are sputtered by ion beams, whereas amorphous materials are less susceptible to this phenomenon.1 Several techniques have been employed to reduce this interface broadening problem. Amongst them have been reactive ion beam sputtering,2 ion sputtering with two ion beams at opposing angles,3,4 and finally, ion sputtering while the specimen is being mechanically rotated3,5,6. We elaborate upon this last technique, using a more stable sample rotation device, supporting Zalar's results that the depth resolution of a polycrystalline thin film material is nearly independent of depth. Further results indicate that the measured interface widths were independent of ion beam accelerating voltage between 1.0 and 3.0 keV only when sample rotation was applied; and that the loss of depth resolution near the specimen surface and within bulk occurs as a result of mono‐directional ion beam sputtering. We have also demonstrated that surface roughness can actually be reduced by rotation during sputtering, thereby restoring the interface depth resolution.Keywords
This publication has 10 references indexed in Scilit:
- Ion sputtering yield measurements for submicrometer thin filmsJournal of Vacuum Science & Technology A, 1988
- Sample rotating in Auger electron spectroscopy depth profilingJournal of Vacuum Science & Technology A, 1987
- Superposition of Auger electron spectroscopy depth profiles obtained on Cr/Ni multilayer samples with different roughnessesJournal of Vacuum Science & Technology A, 1987
- Nickel-chromium interface resolution in Auger depth profilesSurface Science, 1986
- Determination of depth resolution from measured sputtering profiles of multilayer structures: Equations and approximationsSurface and Interface Analysis, 1986
- Improved depth resolution by sample rotation during Auger electron spectroscopy depth profilingThin Solid Films, 1985
- A novel CMA alignment technique for Auger spectroscopyApplications of Surface Science, 1984
- Limitations of ion etching for interface analysisSurface and Interface Analysis, 1981
- Improved sputter-depth profiles using two ion gunsApplications of Surface Science, 1980
- Improved depth resolution in Auger depth profiling of multilayered thin films by reactive ion sputteringSurface and Interface Analysis, 1979