Magnetic Resonance Imaging versus Multislice Computed Tomography of Thoracic Aortic Endografts
- 1 June 2002
- journal article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 9 (2_suppl)
- https://doi.org/10.1177/15266028020090s202
Abstract
Purpose: To compare the potential of magnetic resonance imaging (MRI) to multislice computed tomography (CT) for evaluating stent-graft placement in the thoracic aorta. Methods: Susceptibility artifacts in 2 different stent-graft systems (Talent and Excluder) were evaluated in vitro in 2 angulations (straight and 33° curved) using 3 different MRI gradient echo sequences (True FISP, 2-dimensional FLASH, and 3-dimensional Turbo FLASH). The size of the stent-related artifact was measured, and the relative stent lumen was calculated. In vivo stent demarcation, stent patency, and additional findings were determined in 13 patients (3 Talent, 9 Excluder, and 1 combined) and compared to CT findings. Results: In vitro, both endograft systems proved to be MR compatible, with the relative stent lumen value ranging from 82% to 100% in the straight configuration; in a curved model, the relative stent lumen value ranged from 56% to 92% with the 3D Turbo FLASH sequence, which provided the smallest susceptibility artifacts. The Excluder endoprosthesis caused significant signal inhomogeneity within the stent in a curved configuration. In vivo, MRI and multislice CT showed similar results, with CT imaging slightly superior in stent demarcation and MRI better in demonstrating thrombus. CT beam hardening artifacts were pronounced in the Talent system, while the Excluder device caused significant signal inhomogeneity within the stent on magnetic resonance angiography. Conclusions: Multislice CT and contrast-enhanced MRI are fast, reliable means of providing all relevant information for surveillance of fully MR-compatible stent-grafts in the thoracic aorta.Keywords
This publication has 29 references indexed in Scilit:
- Stent-Artefakte in der 3D MR Angiographie: Experimentelle StudienRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000
- Stentangioplastie von Beckenarterienstenosen unter MRT-Kontrolle: Erste klinische ErgebnisseRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000
- Three-dimensional MR angiography of a nitinol-based abdominal aortic stent graft: assessment of heating and imaging characteristicsEuropean Radiology, 1999
- Metallic stents: evaluation of MR imaging safety.American Journal of Roentgenology, 1999
- The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aortaThe Journal of Thoracic and Cardiovascular Surgery, 1998
- Endoluminal Stent–Grafts for Infrarenal Abdominal Aortic AneurysmsNew England Journal of Medicine, 1997
- Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 TeslaCardioVascular and Interventional Radiology, 1996
- Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation.American Journal of Roentgenology, 1996
- Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT.American Journal of Roentgenology, 1995
- Susceptibility artefacts in NMR imagingMagnetic Resonance Imaging, 1985