Fully Automated 96-Well Liquid−Liquid Extraction for Analysis of Biological Samples by Liquid Chromatography with Tandem Mass Spectrometry
- 21 December 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (3) , 708-714
- https://doi.org/10.1021/ac001036c
Abstract
A fully automated high-throughput liquid−liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC−MS/MS). The LC−MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC−MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids. The complete bioanalytical method, based on the automated LLE and fast gradient LC−MS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.Keywords
This publication has 12 references indexed in Scilit:
- Peer Reviewed: Split-Flow Thin Fractionation.Analytical Chemistry, 2000
- Automated protein precipitation by filtration in the 96-well formatJournal of Chromatography B: Biomedical Sciences and Applications, 1999
- Comparison of plasma sample purification by manual liquid–liquid extraction, automated 96-well liquid–liquid extraction and automated 96-well solid-phase extraction for analysis by high-performance liquid chromatography with tandem mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1999
- Rapid determination of the anti-cancer drug chlorambucil (Leukeran™) and its phenyl acetic acid mustard metabolite in human serum and plasma by automated solid-phase extraction and liquid chromatography–tandem mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1999
- Design and Therapeutic Application of Matrix Metalloproteinase InhibitorsChemical Reviews, 1999
- The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compoundsRapid Communications in Mass Spectrometry, 1999
- Liquid−Liquid Extraction in the 96-Well Plate Format with SRM LC/MS Quantitative Determination of Methotrexate and Its Major Metabolite in Human PlasmaAnalytical Chemistry, 1999
- Peer Reviewed: Sample Preparation for LC/MS/MS: Analyzing Biological and Environmental SamplesAnalytical Chemistry, 1998
- Matrix Effect in Quantitative LC/MS/MS Analyses of Biological Fluids: A Method for Determination of Finasteride in Human Plasma at Picogram Per Milliliter ConcentrationsAnalytical Chemistry, 1998
- Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppressionJournal of the American Society for Mass Spectrometry, 1996