Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry
- 1 November 2001
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 27 (11) , 1787-1791
- https://doi.org/10.1016/s0886-3350(01)00900-2
Abstract
To assess whether there is a significant difference in intraocular pressure (IOP) measurements between noncontact and applanation methods and if so, whether the difference is correlated with corneal thickness. Işik Eye Clinic, Ankara, Turkey. This prospective study comprised 120 eyes of 60 randomly selected patients. Noncontact tonometry, applanation tonometry, and pachymetry were performed in each eye. The results were compared and an analysis was performed to determine whether there was a correlation between the differences in IOP measurements and corneal thickness in the entire group and in subgroups composed of the halves and quarters of the group. The mean IOP in the entire group was 20.38 mm Hg +/- 4.97 (SD) with the noncontact tonometer and 18.84 +/- 4.47 mm Hg with the Goldmann applanation tonometer. The difference between the measurements with the noncontact method and those with the applanation method was statistically significant (P <.01) except in cases having a corneal thickness between 513 microm and 539 microm (P >.01). There was a positive correlation between corneal thickness and the difference in measurements by noncontact and applanation tonometry, and the magnitude of correlation was greater in cases with thicker corneas. The reliability of tonometers decreased with increasing corneal thickness, in which case higher readings were found, especially with the noncontact tonometer.Keywords
This publication has 18 references indexed in Scilit:
- Airpuff tonometry versus applanation tonometryActa Ophthalmologica, 2009
- Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomyOphthalmology, 1998
- Tonometry in adults and childrenOphthalmology, 1998
- Reproducibility with the Keeler Pulsair 2000 non-contact tonometer.British Journal of Ophthalmology, 1995
- Comparison of the Keeler Pulsair 2000 non-contact tonometer with Goldmann applanationEye, 1993
- Evaluation of the Keeler Pulsair non‐contact tonometerActa Ophthalmologica, 1989
- Comparison of a new non-contact tonometer with Goldmann applanationEye, 1989
- A new handheld air impulse tonometerEye, 1988
- Increased Corneal Thickness Simulating Elevated Intraocular PressureArchives of Ophthalmology (1950), 1978
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975