Linear combination of multiecho data: Short T2 component selection
- 25 February 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (3) , 495-502
- https://doi.org/10.1002/mrm.10713
Abstract
The myelin sheath, which is wrapped around the axons in the brain, can be affected by many diseases, resulting in cognitive and physical disability. Other work showed water in the myelin sheath has a T2 ≈ 15 ms. The current standard technique to estimate the fraction of myelin water in vivo is to collect multiecho data and fit the decay curves using a nonnegative least‐squares (NNLS) algorithm. A new algorithm was developed to calculate optimized coefficients which were used to linearly combine multiecho data to estimate the myelin water signal. A set of simulations showed the new technique was accurate over a broad range of myelin water signal. The myelin water fraction from brain regions in scans from five volunteers, estimated by the linear combination method, agreed with the myelin water fraction estimated by the standard technique. The strength of the new technique is that the linear combination does not assume an underlying T2 model and is 20,000 times faster than NNLS. Magn Reson Med 51:495–502, 2004.Keywords
Funding Information
- Multiple Sclerosis Society of Canada
- BC Children's Hospital
- University of British Columbia
This publication has 19 references indexed in Scilit:
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- In vivo visualization of myelin water in brain by magnetic resonanceMagnetic Resonance in Medicine, 1994
- Spin‐spin relaxation in experimental allergic Encephalomyelitis. Analysis of CPMG data using a non‐linear least squares method and linear inverse theoryMagnetic Resonance in Medicine, 1993
- Practical T2 quantitation for clinical applicationsJournal of Magnetic Resonance Imaging, 1992
- Investigation of analysis techniques for complicated NMR relaxation dataJournal of Magnetic Resonance (1969), 1991
- Application of continuous relaxation time distributions to the fitting of data from model systmes and excised tissueMagnetic Resonance in Medicine, 1991
- Quantitative interpretation of NMR relaxation dataJournal of Magnetic Resonance (1969), 1989
- Analysis of biological NMR relaxation data with continuous distributions of relaxation timesJournal of Magnetic Resonance (1969), 1986
- Compensation for pulse imperfections in NMR spin-echo experimentsJournal of Magnetic Resonance (1969), 1981
- Water compartments in the myelinated nerve. III. Pulsed NMR resultCellular and Molecular Life Sciences, 1978