Ceramic Bearing Surfaces
- 1 December 1999
- journal article
- review article
- Published by Wolters Kluwer Health
- Vol. 369 (369) , 83-91
- https://doi.org/10.1097/00003086-199912000-00009
Abstract
Despite more than 25 years of clinical experience with ceramic materials as bearing surfaces, their role in modern joint replacement surgery remains to be clearly defined. The two primary materials are alumina and zirconia. The application of these materials is primarily as a femoral head bearing surface against polyethylene, but alumina also is used as a femoral head and an acetabulum to provide a polyethylene-free bearing surface. Important issues that must be clarified for these materials to gain wide acceptance are the material properties, wear rates against polyethylene and alumina, the biologic response to ceramic wear debris, and cost in relation to indications. The bulk materials are biocompatible, hard, wettable, high-strength, and can yield good surface finishes. Linear polyethylene wear against alumina heads is reported to be as much as a factor of 5 to 10 lower than metal versus polyethylene. Thus, the ceramic femoral head may be a good choice for the younger patient in whom it seems necessary to use a larger head for stability reasons with a polyethylene cup. Ceramic-on-ceramic wear rates are in the range of 0.003 mm/year, a factor of 10 less than the lowest polyethylene wear rates. These costly materials are limited in head and neck sizes because of statistical variation in strength that can lead to fracture. Occasional reports of high alumina-on-alumina wear have appeared. Many of the problems of the past have been design, manufacture, or application related, and have been improved or eliminated. Proper clinical technique in the use of ceramic femoral heads is crucial to prevent fracture. The materials hold high promise and should continue to be used so that additional experience can help define the clinical indications for components made of these materials.Keywords
This publication has 23 references indexed in Scilit:
- Diamond Coated Total Hip ReplacementsPublished by Wolters Kluwer Health ,1998
- Alternative Bearing Surfaces for Total Joint ArthroplastyJournal of the American Academy of Orthopaedic Surgeons, 1998
- FEMORAL COMPONENT WEAR IN RETRIEVED HIP PROSTHESESThe Journal of Bone and Joint Surgery. British volume, 1997
- Wear of retrieved cemented polyethylene acetabula with alumina femoral headsThe Journal of Arthroplasty, 1997
- Wear characteristics of ceramic-on-ceramic for hip endoprosthesesBiomaterials, 1997
- Charnley wear model for validation of hip simulators' ball diameter versus polytetrafluoroethylene and polyethylene wearProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Hip-simulator ranking of polyethylene wear:Comparisons between ceramic heads of different sizesActa Orthopaedica, 1996
- Unusual foreign-body reaction to a failed total knee replacementJournal of Bone and Joint Surgery, 1995
- Wear Debris in Total Joint ReplacementsJournal of the American Academy of Orthopaedic Surgeons, 1994
- Long-term results of uncemented alumina acetabular implantsThe Journal of Bone and Joint Surgery. British volume, 1994