Resistance and Stability of A New Method for Bonding Biological Materials Using Sutures and Biological Adhesives
- 1 January 2005
- journal article
- research article
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 19 (3) , 215-236
- https://doi.org/10.1177/0885328205046633
Abstract
The valve leaflets of cardiac bioprostheses are secured and shaped by sutures which, given their high degree of resistance and poor elasticity, have been implicated in the generation of stresses within the leaflets, contributing to the failure of the bioprostheses. Bioadhesives are bonding materials that have begun to be utilized in surgery, although there is a lack of experience in their use with inert tissues or bioprostheses. Tensile testing is performed until rupture in samples of calf pericardium, a biomaterial employed in the manufacture of bioprosthetic heart valve leaflets. One hundred and thirty-two trials are carried out in three types of samples: intact or control tissue (n = 12); samples transected and glued in an overlapping manner with a cyanoacrylate (n = 60); and samples transected, sewn with a commercially available suture material and reinforced at the suture holes with the same cyanoacrylate (n = 60). Seven days after their preparation, 12 samples from each group, including the controls, are subjected to tensile testing until rupture and the findings are compared. In the stability study, groups of 12 each of the remaining 48 glued and 48 sutured and glued samples underwent tensile testing until rupture on days 30, 60, 90, and 120, after their preparation. The results show that bonding with the adhesive provided a resistance ranging between 1.04 and 1.87 kg, probably insufficient for use in valve leaflets, but also afforded a high degree of elasticity. After 120 days, both the glued and the sutured and glued series show excellent elastic behavior, with no rigidity or hardening of the pericardium. These samples present reversible elongation, or strain, when they surpass their elastic limit at rupture. This finding may be due to a load concentration that is damaging to the pericardium, to the behavior of the tissue as an amorphous material, or perhaps to both circumstances. These results need to be confirmed in future studies as they may be of value in the design and manufacture of cardiac bioprostheses.Keywords
This publication has 28 references indexed in Scilit:
- Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valvesJournal of Biomedical Materials Research, 2002
- Selection and interaction of biomaterials used in the construction of cardiac bioprosthesesJournal of Biomedical Materials Research, 1998
- Viscoelasticity of dynamically fixed bioprosthetic valves. II. Effect of glutaraldehyde concentrationThe Journal of Thoracic and Cardiovascular Surgery, 1997
- Elastic behaviour of sutured calf pericardium: influence of the suture threadsBiomaterials, 1996
- Cytotoxicity testing of cyanoacrylates using direct contact assay on cell culturesBiomaterials, 1994
- Collagen Fiber Architecture of Bovine PericardiumAsaio Journal, 1994
- Effect of the suture on the durability of bovine pericardium used in cardiac bioprosthesesBiomaterials, 1994
- Anisotropic elasticity and strength of glutaraldehyde fixed bovine pericardium for use in pericardial bioprosthetic valvesJournal of Biomedical Materials Research, 1994
- Study of the calcification of bovine pericardium: analysis of the implication of lipids and proteoglycansBiomaterials, 1991
- In vitro toxicity test of 2‐cyanoacrylate polymers by cell culture methodJournal of Biomedical Materials Research, 1990