Randomized Comparison Between Open Irrigation Technology and Intracardiac‐Echo‐Guided Energy Delivery for Pulmonary Vein Antrum Isolation: Procedural Parameters, Outcomes, and the Effect on Esophageal Injury
- 9 May 2007
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (6) , 583-588
- https://doi.org/10.1111/j.1540-8167.2007.00879.x
Abstract
We performed a prospective study to compare efficacy and safety of both open irrigation tip (OIT) technology with intracardiac echo (ICE)-guided energy delivery in patients presenting for PVAI. Fifty-three patients presenting for PVAI were randomized to ablation using an OIT catheter (Group 1, 26 patients; temperature and power were set at 50 degrees and 50 W, respectively, with a saline pump flow rate of 30 mL/min) or radiofrequency (RF) energy delivery under ICE guidance (Group 2, 27 patients; energy was titrated based on microbubbles formation). The mean procedure time and fluoroscopy exposure were lower in Group 1 (164 +/- 42 min and 7,560 +/- 2,298 microGray m2 vs 204 +/- 47 min and 12,240 +/- 4,356 microGray m2; P = 0.005 and 0.008, respectively). Moreover, the durations of RF lesions applied per PV antrum was lower in Group 1 compared with Group 2 (5.1 +/- 2.2 min vs 9.2 +/- 3.2 min, P = 0.03, respectively). Within 24 hours after PVAI in 35.7% (all erythema) of Group 1 and 57.1% (21.4% erythema and 35.7% necrosis) of Group 2, patients' esophageal wall changes were documented. After 14 +/- 2 months of follow up, recurrences were documented in 19.2% of Group 1 and 22.2% of Group 2 patients. Although both OIT and ICE-guided energy delivery possess a similar effect in treating AF, OIT seems to be superior in terms of achieving isolation and shortening fluoroscopy exposure. Moreover, a lower incidence of esophageal wall injury was observed utilizing OIT for PVAI.Keywords
This publication has 33 references indexed in Scilit:
- Electrophysiologic and Anatomic Characterization of Sites Resistant to Electrical Isolation During Circumferential Pulmonary Vein Ablation for Atrial Fibrillation: A Prospective StudyJournal of Cardiovascular Electrophysiology, 2007
- Comparison of Cool Tip Versus 8‐mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long‐Term Control of Atrial Fibrillation: A Prospective Randomized Pilot StudyJournal of Cardiovascular Electrophysiology, 2006
- Avoiding Microbubbles Formation During Radiofrequency Left Atrial Ablation Versus Continuous Microbubbles Formation and Standard Radiofrequency Ablation Protocols: Comparison of Energy Profiles and Chronic Lesion CharacteristicsJournal of Cardiovascular Electrophysiology, 2006
- Electrophysiological Findings During Ablation of Persistent Atrial Fibrillation With Electroanatomic Mapping and Double Lasso Catheter TechniqueCirculation, 2005
- Randomized comparison of encircling and nonencircling left atrial ablation for chronic atrial fibrillationHeart Rhythm, 2005
- Embolic Events and Char Formation During Pulmonary Vein Isolation in Patients with Atrial Fibrillation: Impact of Different Anticoagulation Regimens and Importance of Intracardiac Echo ImagingJournal of Cardiovascular Electrophysiology, 2005
- Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary VeinCirculation, 2004
- Complete Isolation of Left Atrium Surrounding the Pulmonary VeinsCirculation, 2004
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter*1Published by Oxford University Press (OUP) ,2004