A pencil‐beam photon dose algorithm for stereotactic radiosurgery using a miniature multileaf collimator
- 2 June 1998
- journal article
- Published by Wiley in Medical Physics
- Vol. 25 (6) , 841-850
- https://doi.org/10.1118/1.598294
Abstract
A computer-controlled miniature multileaf collimator (MMLC) with 4 mm leaf width and a maximum field size of 6 cm X 6 cm has been designed as a tertiary beam-shaping device for linac-based stereotactic radiosurgery. The purpose of this study is to develop an accurate and efficient dose calculation model for use with the MMLC. A pencil-beam based algorithm using a sum of three Gaussian kernels was developed to model the off-axis ratio of MMLC fields. Because the kernel integration over a rectangular field can be solved in closed form, dose to any point from an arbitrary MMLC field can be calculated efficiently by summing dose contribution from a set of rectangular apertures and transmission blocks that model individual leaf openings or leaf transmissions. The model uses an effective rectangular field and equivalent square method for determination of depth dose and dose output. Results showed that the calculated percentage depth dose was within 1% and output factor was within 1.5% of measured data. The parameters of the pencil beam kernels were extracted by fitting measured off-axis profiles for a few field sizes at a few depths. The accuracy of the calculated off-axis ratio was tested by comparison with measured data for a number of MMLC fields. The algorithm was shown to be accurate to within 1.5% or 1 mm for off-axis ratios. The algorithm computes at a speed of 34,600 data points per second on a DEC Alpha server model 2000/433 (Digital Equipment Corp., Maynard, MA), which is about 15 times faster than a Clarkson-type summation method.Keywords
This publication has 11 references indexed in Scilit:
- Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam modelMedical Physics, 1997
- Comparison of Miniature Multileaf Collimation (MMLC) with circular collimation for stereotactic treatmentInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Dosimetry of high energy photon and electron beams with CEA filmsMedical Physics, 1996
- Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x‐ray beamsMedical Physics, 1995
- A Monte Carlo study of accelerator head scatterMedical Physics, 1994
- The design and performance characteristics of a multileaf collimatorPhysics in Medicine & Biology, 1994
- X‐ray sources of medical linear accelerators: Focal and extra‐focal radiationMedical Physics, 1993
- Characterization of a multileaf collimator systemInternational Journal of Radiation Oncology*Biology*Physics, 1993
- On the field-size dependence of relative output from a linear acceleratorMedical Physics, 1992
- Measurement of dose distributions using film in therapeutic electron beamsMedical Physics, 1989