An Evaluation of Image Noise Variance for Time-of-Flight PET
- 21 March 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2041-2045
- https://doi.org/10.1109/nssmic.2005.1596734
Abstract
We describe a simple theoretical framework for linear time-of-flight (TOF) reconstruction and evaluate several alternative TOF filters. We implement a capability for direct computation of TOF noise variance images and evaluate the gain in image variance for TOF vs. non-TOF for 1.26 nsec TOF resolution on the Siemens biograph HiRez PET/CT. The variance calculation is validated by comparing to pixel variances computed from replicated synthetic data. TOF reconstruction does not give a uniform improvement in image noise variance, but improves variance more toward the periphery of an object than at its center. The TOF performance gain depends on how random coincidences are processed, and is greater when the randoms fraction is higher, or when randoms smoothing is not employed. We confirm that TOF gain is greater for larger objects than for smaller ones, but find discrepancies with the D/Deltax rule of thumb. With 1.26 nsec resolution on the HiRez, TOF image noise gain factors (non-TOF/TOF variance) range from 1.5 to 2.2 on the measured data at hand. We predict that an improvement in TOF resolution by a factor of 2 (to 600 psec) could improve image variance on this machine by an additional factor of 1.8. We find that confidence weighted TOF reconstruction under-performs non-TOF reconstruction for objects whose diameters are small compared to the TOF resolutionKeywords
This publication has 14 references indexed in Scilit:
- The Effects of Object Size, Attenuation, Scatter, and Random Coincidences on Signal to Noise Ratio in Simulations of Time-of-Flight Positron Emission TomographyPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- Effect of Randoms on Signal-to-Noise-Ratio in TOF PETPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- Extension of Single Scatter Simulation to Scatter Correction of Time-of-Flight PETPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- First experimental results of time-of-flight reconstruction on an LSO PET scannerPhysics in Medicine & Biology, 2005
- Comparison between three-dimensional positron emission tomography with and without time-of-flight measurementPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Three-dimensional PET reconstruction with time-of-flight measurementPhysics in Medicine & Biology, 1992
- Estimation of the Local Statistical Noise in Emission Computed TomographyIEEE Transactions on Medical Imaging, 1982
- Some Noise Comparisons of Data-Collection Arrays for Emission Tomography-Systems Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1982
- A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1981
- Image Reconstruction and Noise Evaluation in Photon Time-of-Flight Assisted Positron Emission TomographyIEEE Transactions on Nuclear Science, 1981