Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristics
- 27 July 2004
- journal article
- Published by Portland Press Ltd. in Clinical Science
- Vol. 107 (2) , 205-211
- https://doi.org/10.1042/cs20030294
Abstract
Transfer function techniques are increasingly used for non-invasive estimation of central aortic waveform characteristics. Non-invasive radial waveforms must be calibrated for this purpose. Most validation studies have used invasive pressures for calibration, with little data on the impact of non-invasive calibration on transfer-function-derived aortic waveform characteristics. In the present study, simultaneous invasive central aortic (Millar Mikro-tip® catheter transducer) and non-invasive radial (Millar® Mikro-tip® tonometer) pressure waveforms and non-invasive brachial pressures (Dinamap®) were measured in 42 subjects. In this cohort, radial waveforms were calibrated to both invasive and non-invasive mean and diastolic pressures. From each of these, central waveforms were reconstructed using a generalized transfer function obtained by us from a previous cohort [Hope, Tay, Meredith and Cameron (2002) Am. J. Physiol. Heart Circ. Physiol. 283, H1150–H1156]. Waveforms were analysed for parameters of potential clinical interest. For calibrated radial and reconstructed central waveforms, different methods of calibration were associated with differences in pressure (P<0.001), but not time parameters or augmentation index. Whereas invasive calibration resulted in little error in transfer function estimation of central systolic pressure (difference −1±8 mmHg; P=not significant), non-invasive calibration resulted in significant underestimation (7±12 mmHg; P<0.001). Errors in estimated aortic parameters differed with non-invasively calibrated untransformed radial and transfer-function-derived aortic waveforms (all P<0.01), with smaller absolute errors with untransformed radial waveforms for most pressure parameters [systolic pressure, 5±16 and 7±12 mmHg; pulse pressure, 0±16 and 4±12 mmHg (radial and derived aortic respectively)]. When only non-invasive pressures are accessible, analysis of untransformed radial waveforms apparently produces smaller errors in the estimation of central aortic systolic pressure, and other waveform parameters, than using a generalized transfer function.Keywords
This publication has 25 references indexed in Scilit:
- Clinical Utility of Aortic Pulses and Pressures Calculated From Applanated Radial-Artery PulsesHypertension, 2003
- Use of arterial transfer functions for the derivation of aortic waveform characteristicsJournal Of Hypertension, 2003
- Influence of drugs and gender on the arterial pulse wave and natriuretic peptide secretion in untreated patients with essential hypertensionClinical Science, 2002
- Reproducibility of derived central arterial waveforms in patients with chronic renal failureClinical Science, 2002
- Pulse-Wave AnalysisArteriosclerosis, Thrombosis, and Vascular Biology, 2002
- Prospective Evaluation of a Method for Estimating Ascending Aortic Pressure From the Radial Artery Pressure WaveformHypertension, 2001
- Arterial Stiffness as Underlying Mechanism of Disagreement Between an Oscillometric Blood Pressure Monitor and a SphygmomanometerHypertension, 2000
- Where is the evidence that radial artery tonometry can be used to accurately and noninvasively predict central aortic blood pressure in patients with diabetes?Diabetes Care, 2000
- National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.Hypertension, 1993
- Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.Hypertension, 1990