Quantification of in‐plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification
- 1 May 1998
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 8 (3) , 568-576
- https://doi.org/10.1002/jmri.1880080309
Abstract
Motion of the coronary arteries during the heart cycle can result in image blurring and inaccurate flow quantification by MR. This condition applies particularly for longer acquisition windows that are typical of breath‐hold coronary flow measurements. To determine the sensitivity of the technique to in‐plane motion of different coronary arteries, the temporal variation in coronary position was measured in a plane perpendicular to the proximal portion of the vessel. The results indicated the presence of substantial displacement of the coronary arteries within the cardiac cycle, with a magnitude of motion approximately twice as large for the right as for the left coronary arteries. An estimation of the resulting vessel blurring was calculated, showing that the duration of the acquisition window for high spatial resolution coronary flow acquisitions should be less than 25 to 120 msec, depending on the specific coronary artery studied. In addition, these data specify optimal acquisition window placement for high resolution coronary angiography.Keywords
This publication has 21 references indexed in Scilit:
- Velocity‐encoded, phase‐difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine framesJournal of Magnetic Resonance Imaging, 1996
- Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance ImagingCirculation, 1996
- Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: Effects of cardiac and respiratory motionMagnetic Resonance in Medicine, 1996
- Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging.Radiology, 1996
- Protocol for two-dimensional magnetic resonance coronary angiography studied in three-dimensional magnetic resonance data setsAmerican Heart Journal, 1995
- Measurement of Absolute Epicardial Coronary Artery Flow and Flow Reserve With Breath-Hold Cine Phase-Contrast Magnetic Resonance ImagingCirculation, 1995
- Respiratory Blur in 3D Coronary MR ImagingMagnetic Resonance in Medicine, 1995
- The application of breath hold phase velocity mapping techniques to the measurement of coronary artery blood flow velocity: Phantom data and initial in vivo resultsMagnetic Resonance in Medicine, 1994
- Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.Radiology, 1991
- Methods for Evaluating Cardiac Wall Motion in Three Dimensions Using Bifurcation Points of the Coronary Arterial TreeInvestigative Radiology, 1983