Effects of sample geometry and electrode configuration on measured electrical resistivity of skeletal muscle
- 1 January 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 47 (2) , 163-169
- https://doi.org/10.1109/10.821749
Abstract
Over the past 40 years, researchers from a variety of scientific backgrounds have been using Rush's equations to analyze results of their electrophysiological studies. A lack of understanding of the constraints and the domain in which these equations are valid, often results in situations in which it is challenging to evaluate and compare results obtained by different investigators. In this paper, we reanalyzed the conditions for which Rush's equations were derived, and using mathematical modeling, computer simulation and in vitro measurements, we delineated areas of their appropriate application. Our studies showed that both sample geometry and test electrode configuration affect the measured tissue electrical resistivities: 1) The sample can be considered semi-infinite only if its dimensions are > 50 inter-electrode separation distances (IESD), and thickness > 2.5 IESD, 2) smaller sample sizes increase the transversally measured resistivity, 3) semi-infinite samples thinner than 2.5 IESD, and samples tested with needle electrodes demonstrate reduced anisotropy, and 4) when surface-spot electrodes are longitudinally aligned, as the IESD/tissue thickness ratio decreases, the measured resistivity increases. Our conclusion is that in most experimental situations, it is necessary to use modeling techniques to decouple the electrode configuration/sample geometry influence from the measured tissue resistivity.Keywords
This publication has 12 references indexed in Scilit:
- Effects of current frequency, fiber orientation and sample thickness on the measured resistivity of skeletal musclePublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Isotropic and homogeneous approximation of myocardial tissue resistivity behaviorPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Geometric effects on resistivity measurements with four-electrode probes in isotropic and anisotropic tissuesIEEE Transactions on Biomedical Engineering, 1998
- The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivoIEEE Transactions on Biomedical Engineering, 1993
- The effects of spiral anisotropy on the electric potential and the magnetic field at the apex of the heartMathematical Biosciences, 1988
- Electrical conductivity of skeletal muscle tissue: Experimental results from different musclesin vivoMedical & Biological Engineering & Computing, 1984
- Impedance of Skeletal Muscle from 1 Hz to 1 MHzIEEE Transactions on Biomedical Engineering, 1984
- The Four-Electrode Resistivity Technique as Applied to Cardiac MuscleIEEE Transactions on Biomedical Engineering, 1982
- AVERAGING TECHNIQUES EMPLOYING SEVERAL SIMULTANEOUS PHYSIOLOGICAL VARIABLESAnnals of the New York Academy of Sciences, 1964
- Resistivity of Body Tissues at Low FrequenciesCirculation Research, 1963