Noncontact Mapping of the Left Ventricle:
- 4 May 2004
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (5) , 570-578
- https://doi.org/10.1111/j.1540-8159.2004.00489.x
Abstract
It is not clear whether the noncontact electrograms obtained using the EnSite system in the left ventricle resemble most closely endocardial, intramural, or epicardial contact electrograms or a summation of transmural electrograms. This study compared unipolar virtual electrograms from the EnSite system with unipolar contact electrograms from transmural plunge needle electrodes using a 256-channel mapping system. The study also evaluated the effects of differing activation sites (endocardial, intramural, or epicardial). A grid of 50-60 plunge needles was positioned in the left ventricles of eight male sheep. Each needle had four electrodes to record from the endocardium, two intramural sites, and the epicardium. Correlations between contact and noncontact electrograms were calculated on 32,242 electrograms. Noncontact electrograms correlated equally well in morphology and accuracy of timing with endocardial (0.88 +/- 0.15), intramural (0.87 +/- 0.15), epicardial (0.88 +/- 0.15), and transmural summation contact electrograms (0.89 +/- 0.14) during sinus rhythm, endocardial pacing, and epicardial pacing. There was a nonlinear relationship between noncontact electrogram accuracy as measured by correlation with the contact electrogram and distance from the multielectrode array (MEA): beyond 40 mm accuracy decreased rapidly. The accuracy of noncontact electrograms also decreased with increasing distance from the equator of the MEA. Virtual electrograms from noncontact mapping of normal left ventricles probably represent a summation of transmural activation. Noncontact mapping has similar accuracy with either endocardial or epicardial sites of origin of electrical activity provided the MEA is within 40 mm of the recording site.Keywords
This publication has 18 references indexed in Scilit:
- Noncontact mapping to guide ablation of right ventricular outflow tract tachycardiaJournal of the American College of Cardiology, 2002
- Characteristics of Wavefront Propagation in Reentrant Circuits Causing Human Ventricular TachycardiaCirculation, 2002
- Non-contact mapping to guide catheter ablation of untolerated ventricular tachycardiaEuropean Heart Journal, 2002
- Electrophysiologic Endocardial Mapping from a Noncontact Nonexpandable Catheter: A Validation Study of a Geometry‐Based ConceptJournal of Cardiovascular Electrophysiology, 2000
- Spatial regularization of the electrocardiographic inverse problem and its application to endocardial mappingIEEE Transactions on Biomedical Engineering, 2000
- Simultaneous Endocardial Mapping in the Human Left Ventricle Using a Noncontact CatheterCirculation, 1998
- Digital Signal Processing Chip Implementation for Detection and Analysis of Intracardiac ElectrogramsPacing and Clinical Electrophysiology, 1994
- Functional role of the epicardium in postinfarction ventricular tachycardia. Observations derived from computerized epicardial activation mapping, entrainment, and epicardial laser photoablation.Circulation, 1991
- Identification of Ventricular Tachycardia Using Intracardiac Electrograms: A Comparison of Unipolar Versus Bipolar Waveform AnalysisPacing and Clinical Electrophysiology, 1991
- Reentry as a cause of ventricular tachycardia in patients with chronic ischemic heart disease: electrophysiologic and anatomic correlation.Circulation, 1988