Reliability and Validity of Measures of Cardiac Output During Incremental to Maximal Aerobic Exercise
- 1 January 1999
- journal article
- review article
- Published by Springer Nature in Sports Medicine
- Vol. 27 (1) , 23-41
- https://doi.org/10.2165/00007256-199927010-00003
Abstract
The assessment of cardiac function, particularly cardiac output (Q̇) during heavy exercise is essential for the evaluation of cardiovascular factors that might limit oxygen transport. A series of invasive and noninvasive techniques has been developed for the assessment and monitoring of Q̇ during resting and submaximal exercise conditions. However, very few techniques have been found to give accurate and reliable determinations of Q̇ during vigorous to maximum exercise. For exercise physiologists and sport cardiologists, maximal exercise data are of primary importance. The ‘gold standard’ measures of cardiac function are considered to be the direct Fick and dye-dilution methods. These have been widely shown to give accurate and reliable determinations of Q̇ during resting and submaximal exercise conditions; however, their use during maximal exercise conditions is debatable due to the inherent risks involved with each and their increasing inaccuracy during the later stages of vigorous exercise. Thermodilution has also been considered to be a relatively good method for the determination of Q̇ during rest and exercise conditions, but recent authors have questioned its use due to the nature of the measure and its inaccuracy during strenuous exercise. Various noninvasive measures of cardiac function have been developed to overcome the problems associated with the ‘gold standard’ measures. The first part of this article discusses conventional techniques used in exercise physiology settings. The majority of these provide accurate and reliable determinations of Q̇ during rest and submaximal exercise. However, very few techniques are suitable for maximal exercise conditions. Perhaps only the foreign gas rebreathe using acetylene (C2H2) meets all the criteria of being noninvasive, simple to use, reliable over repeated measurements, accurate and useful during maximal exercise.Keywords
This publication has 93 references indexed in Scilit:
- Respiratory Function of HemoglobinNew England Journal of Medicine, 1998
- Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.Heart, 1990
- Evaluation of a modified acetylene rebreathing method for the determination of cardiac outputClinical Physiology and Functional Imaging, 1986
- Analysis of factors affecting the variability of fick versus indicator dilution measurements of cardiac outputThe American Journal of Cardiology, 1985
- Cardiac output determination by simple one-step rebreathing techniqueRespiration Physiology, 1976
- Physical Training in Sedentary Middle-aged and Older Men III. Cardiac Output and Gas Exchange at Submaximal and Maximal ExerciseScandinavian Journal of Clinical and Laboratory Investigation, 1969
- Serial determinations of cardiac output at rest.Heart, 1965
- Cardiac Output in Healthy Subjects Determined with a CO2Rebreathing MethodActa Physiologica Scandinavica, 1963
- The Reproducibility of Cardiac Output Determination by the Direct Fick Method During Muscular WorkScandinavian Journal of Clinical and Laboratory Investigation, 1960
- Estimation of cardiac output in man by dye dilution method using an automatic computing oximeterAmerican Heart Journal, 1958