Crystal damage, caused by a 1015 11B/cm2 250-keV implant into epitaxial Hg0.64Cd0.36Te layers held at LN2 temperature, has been successfully annealed, as observed by MeV 4He ion channeling and Rutherford backscattering. The anneal consists of a thermal pulse of 250 °C for 8 s in air under a Si proximity cap. Secondary ion mass spectrometry (SIMS) data indicate that the boron did not diffuse during the anneal. An n-p junction was observed at a depth of 5.5 μm by electron beam induced current (EBIC) measurements. A diode fabricated on the layer exhibited a very sharp I-V curve with reverse breakdown occurring at 12 V and an R0A of ⩾107 Ω cm2 at 77 K.Keywords
This publication has 7 references indexed in Scilit:
- Boron ion implantation in Hg1−xCdxTeJournal of Applied Physics, 1982
- Performance of PV HgCdTe arrays for 1-14-µm applicationsIEEE Transactions on Electron Devices, 1982
- cw CO2 and ruby laser annealing of ion-implanted Hg1−xCdx TeApplied Physics Letters, 1981
- Radiation Annealing of Boron-Implanted Silicon with a Halogen LampJapanese Journal of Applied Physics, 1980
- Ion Implantation Study of HgCdTeJapanese Journal of Applied Physics, 1980
- Damage and lattice location studies in Hg implanted Hg1–xCdxTeRadiation Effects, 1980
- Ion implantation doping of Cd0.2Hg0.8Te for infrared detectorsIEEE Transactions on Electron Devices, 1980