In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortex
- 18 April 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 53 (5) , 934-940
- https://doi.org/10.1109/tbme.2006.872824
Abstract
The mechanical behavior of an electrode during implantation into neural tissue can have a profound effect on the neural connections and signaling that takes place within the tissue. The objective of the present work was to investigate the in vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays recently developed by the VSAMUEL consortium (European Union, grant #IST-1999-10073). We have previously reported on both the electrical [1]-[3] and mechanical [4], [5] properties of the ACREO electrodes. In this paper, the tensile and compression forces were measured during a series of in vivo electrode insertions into the cerebral cortex of rats (7 acute experiments, 2-mm implant depth, 2-mm/s insertion velocity). We compared the ACREO silicon electrodes (4' opening angle, 1-8 shafts) to single-shaft tungsten electrodes (3' and 10' opening angles). The penetration force and dimpling increased with the cross-sectional area (statistical difference between the largest and the smallest electrode) and with the number of shafts (no statistical difference). We consistently observed tensile (drag) forces during the retraction phase, which indicates the brain tissue sticks to the electrode within a short time period. Treating the electrodes prior to insertion with silane (hydrophobic) or piranha (hydrophilic) significantly decreased the penetration force. In conclusion, our findings suggest that reusable electrodes for acute animal experiments must not only be strong enough to survive a maximal force that exceeded the penetration force, but must also be able to withstand high tension forces during retraction. Careful cleaning is not only important to avoid foreign body response, but can also reduce the stress applied to the electrode while penetrating the brain tissueKeywords
This publication has 18 references indexed in Scilit:
- Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral CortexIEEE Transactions on Biomedical Engineering, 2004
- Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortexIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2003
- Peripheral stimuli excite coronal beams of Golgi cells in rat cerebellar cortexNeuroscience, 2002
- CHARACTERIZATION OF SILICON MICROELECTRODES FROM THE EU VSAMUEL PROJECTBiomedizinische Technik/Biomedical Engineering, 2001
- TOWARDS A VERSATILE SYSTEM FOR ADVANCED NEURONAL RECORDINGS USING SILICON MULTISITE MICROELECTRODES.Biomedizinische Technik/Biomedical Engineering, 2000
- Chronic intracortical microstimulation (ICMS) of cat sensory cortex using the Utah intracortical electrode arrayIEEE Transactions on Rehabilitation Engineering, 1999
- Measurement of friction on straight catheters in in vitro brain and phantom materialIEEE Transactions on Biomedical Engineering, 1998
- A glass/silicon composite intracortical electrode arrayAnnals of Biomedical Engineering, 1992
- A method for pneumatically inserting an array of penetrating electrodes into cortical tissueAnnals of Biomedical Engineering, 1992
- Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortexIEEE Transactions on Biomedical Engineering, 1992