An MCNP-based model of a linear accelerator x-ray beam
- 1 January 1999
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (5) , 1219-1230
- https://doi.org/10.1088/0031-9155/44/5/010
Abstract
The Monte Carlo N-Particle radiation transport computer code (MCNP) has been employed on a personal computer to develop a simple model simulating the major components within the beam path of a linear accelerator radiation head, namely the electron target, primary conical collimator, beam flattening filter, wedge filter and the secondary collimators. The model was initially used to calculate the energy spectra and angular distributions of the x-ray beam for the Philips SL 75/5 linear accelerator, in a plane immediately beneath the flattening filter. These data were subsequently used as a `source' of x-rays at the target position, to assess the emergent beam from the secondary collimators. The depth dose distributions and dose profiles at constant depth for various field sizes have been calculated for a nominal operating potential of 4 MV and found to be within acceptable limits. It is concluded that the technique may be used to calculate the energy spectra of any linear accelerator upon specification of the component dimensions, materials and nominal accelerating potential. It is anticipated that this work will serve as the basis of a quality control tool for linear accelerators and treatment planning systems.Keywords
This publication has 21 references indexed in Scilit:
- Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses.Physics in Medicine & Biology, 1998
- A CT‐based Monte Carlo simulation tool for dosimetry planning and analysisMedical Physics, 1998
- Reconstruction of 6 MV photon spectra from measured transmission including maximum energy estimationPhysics in Medicine & Biology, 1997
- Monte Carlo simulations of the differential beam hardening effect of a flattening filter on a therapeutic x‐ray beamMedical Physics, 1997
- An analytic calculation of the energy fluence spectrum of a linear acceleratorMedical Physics, 1994
- Simulation of x-ray spectral reconstruction from transmission data by direct resolution of the numeric system AF =TMedical Physics, 1993
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991
- The quality of high-energy X-ray beamsThe British Journal of Radiology, 1989
- Determination of the photon spectrum of a clinical acceleratorMedical Physics, 1984
- Simulation studies of 4‐MV x‐ray spectral reconstruction by numerical analysis of transmission dataMedical Physics, 1982