Selection, Preparation, and Characterization of Commutable Frozen Human Serum Pools as Potential Secondary Reference Materials for Lipid and Apolipoprotein Measurements: Study within the Framework of the Dutch Project “Calibration 2000”
Open Access
- 1 September 2002
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 48 (9) , 1526-1538
- https://doi.org/10.1093/clinchem/48.9.1526
Abstract
Background: The Dutch project “Calibration 2000” aims at harmonization of laboratory results via calibration by development of matrix-based secondary reference materials. We considered the selection, preparation, and characterization of 34 potential reference materials (PRMs). Methods: Sixteen PRMs were prepared either strictly according to the NCCLS C37-A protocol or in a less stringent and more convenient way. In addition, 18 commercial, so-called human serum-based calibrators or controls were purchased and tested. Lipoprotein integrity was evaluated by examining the physicochemical characteristics of the materials. Commutability of the PRMs was assessed in 86 Dutch clinical laboratories, using a multicenter split-patient-sample between-field-method (twin-study) design. Normalized residuals of the PRMs with respect to the patient regression lines were calculated; in addition, the extra contribution of each PRM to the total measurement uncertainty (CVNetto) was calculated. On the basis of these results, the most native PRM was selected to investigate its potential to reduce interlaboratory variation and to improve lipid and apolipoprotein standardization. Results: In general, only the NCCLS C37-A-type materials displayed normalized residuals below the decision limit for commutability and had small CVNetto values ranging between 0 and 3.8%. This contrasts with the findings in regularly pooled frozen sera and lyophilized cryoprotected PRMs. In two subsequent external quality assessment surveys, the NCCLS type C37-A materials contributed to reducing the intermethod lipid and (apo)lipoprotein variation to ∼2–4%. Conclusions: NCCLS C37-A materials have a strong potential as secondary reference materials, not only for cholesterol but also for HDL-cholesterol, LDL-cholesterol, triglyceride, and apolipoprotein measurements.Keywords
This publication has 20 references indexed in Scilit:
- Commutability Assessment of Potential Reference Materials Using a Multicenter Split-Patient-Sample Between-Field-Methods (Twin-Study) Design: Study within the Framework of the Dutch Project “Calibration 2000”Clinical Chemistry, 2002
- Methods for Measurement of LDL-Cholesterol: A Critical Assessment of Direct Measurement by Homogeneous Assays versus CalculationClinical Chemistry, 2002
- Accreditation of reference material producersAccreditation and Quality Assurance, 2001
- A Reference Method Laboratory Network for Cholesterol: A Model for Standardization and Improvement of Clinical Laboratory MeasurementsClinical Chemistry, 2000
- The quest for comparability: Calibration 2000Accreditation and Quality Assurance, 2000
- Laboratory standardization of a large international clinical trial: the DAIS experienceClinical Biochemistry, 2000
- Total Error Evaluation of Roche Direct HDL-Cholesterol Reagent and Calibrator across 31 Lot Combinations: A 2-Year ExperienceClinical Chemistry, 2000
- A New Liquid Homogeneous Assay for HDL Cholesterol Determination Evaluated in Seven Laboratories in Europe and the United Statescclm, 1999
- Survey of Total Error of Precipitation and Homogeneous HDL-Cholesterol Methods and Simultaneous Evaluation of Lyophilized Saccharose-containing Candidate Reference Materials for HDL-CholesterolClinical Chemistry, 1999
- Impact of reference materials on accuracy in clinical chemistryClinical Biochemistry, 1998