Constant-flow Insufflation Prevents Arterial Oxygen Desaturation during Endotracheal Suctioning
- 1 August 1991
- journal article
- Published by American Thoracic Society in American Review of Respiratory Disease
- Vol. 144 (2) , 395-400
- https://doi.org/10.1164/ajrccm/144.2.395
Abstract
In mechanically ventilated patients, disconnection from the ventilator and endotracheal suctioning can induce major arterial oxygen desaturation resulting from apnea, changes in inspired oxygen fraction, and decrease in lung volume. The aim of this study was to test the efficacy of a simple method of delivering oxygen and maintaining lung volume during this process. Our study was conducted in two parts. In the first part, constant-flow insufflation of oxygen (CFI) was used in seven patients ventilated for acute respiratory failure (PaO2/FlO2 = 347 +/- 33 mm Hg) as a means of maintaining arterial oxygenation during apnea and disconnection from the ventilator. CFI was administered via a modified endotracheal tube in which small capillaries allowed delivery of a high-velocity jet flow near the tracheal end of the tube during disconnection from the ventilator. In comparison to apnea alone, CFI prevented a fall in arterial oxygen tension (16 +/- 7 mm Hg during CFI versus 117 +/- 27 during apnea, after 90 s of disconnection in the two situations, p less than 0.001), whereas it did not reduce the development of hypercapnia. The efficacy of CFI resulted both from the injection of oxygen into the trachea and from the maintenance of positive alveolar pressure induced by air entrainment (mean 10.4 +/- 1.1 cm H2O), preventing a fall in lung volume usually occurring after disconnection (+338 +/- 88 ml during CFI versus -344 +/- 64 ml during apnea, p less than 0.01). In the second part of the study CFI was used to prevent arterial oxygen desaturation induced by endotracheal suctioning.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 7 references indexed in Scilit:
- Unsuspected Hemodynamic Alterations during Endotracheal SuctioningChest, 1989
- Gas Exchange during Constant Flow Ventilation with Different GasesAmerican Review of Respiratory Disease, 1987
- Ion range distributions in multilayered structures: Bi in Si/GeJournal of Applied Physics, 1987
- CONTINUOUS FLOW VENTILATION WITHOUT RESPIRATORY MOVEMENT IN CAT, DOG AND HUMANBritish Journal of Anaesthesia, 1986
- Factors Influencing Pulmonary Volumes and CO2 Elimination during High-frequency Jet VentilationAnesthesiology, 1985
- Real-time analysis of the change in arterial oxygen tension during endotracheal suction with a fiberoptic bronchoscopeCritical Care Medicine, 1985
- Prevention of Suctioning-Related Arterial Oxygen DesaturationChest, 1983