Pharmacokinetics of a Degradable Drug Delivery System in Bone
- 1 April 1998
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 349 (349) , 218-224
- https://doi.org/10.1097/00003086-199804000-00027
Abstract
Local delivery of antibiotics via a degradable carrier has the potential for high local antibiotic levels and avoids systemic toxicity. Intravenous access, renal function monitoring, and later surgical removal may not be required when degradable local delivery modalities are used. This study examined the in vivo elution of gentamicin from processed bovine collagen (Type I). Gentamicin impregnated collagen (3 mg/kg) was implanted into the femoral medullary canal of 45 adult white rabbits. The gentamicin was released into the bone and averaged greater than 600 micrograms/ml during the initial 48 hours. Local bone levels fell to 144.40 +/- 229.84 micrograms/ml at 5 days and were subsequently greater than or equal to 10.30 +/- 5.02 micrograms/ml through Day 28. Serum levels reached an average peak of 1.25 +/- 0.29 micrograms/ml 5 hours after implantation and fell below 1.0 microgram/ml at 12 hours after implantation. Serum levels subsequently averaged less than or equal to 0.63 +/- 0.09 microgram/ml through Day 28. Collagen impregnated with gentamicin proved to be an effective degradable carrier of gentamicin in the healthy rabbit; it provided local bone concentrations above the minimum inhibitory concentration of gentamicin and serum concentrations below levels associated with systemic toxicity as long as 28 days after implantation.Keywords
This publication has 8 references indexed in Scilit:
- Gentamicin distribution from a collagen carrierJournal of Orthopaedic Research, 1996
- Treatment of experimental osteomyelitis with antibiotic‐impregnated bone graft substituteJournal of Orthopaedic Research, 1993
- In vitro pharmacokinetics of antibiotic release from locally implantable materialsJournal of Orthopaedic Research, 1993
- Investigation of a Biodegradable, Implantable Antibiotic Delivery System on Rate of Wound InfectionAnnals of Plastic Surgery, 1993
- Experimental implant-related osteomyelitis treated by antibiotic-calcium hydroxyapatite ceramic compositesThe Journal of Bone and Joint Surgery. British volume, 1993
- Fluorescence polarization immunoassay. I. Monitoring aminoglycoside antibiotics in serum and plasma.Clinical Chemistry, 1981
- Experience in Monitoring Gentamicin Therapy during Treatment of Serious Gram-Negative SepsisBMJ, 1974