Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia1
- 1 October 1999
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 25 (10) , 1344-1348
- https://doi.org/10.1016/s0886-3350(99)00202-3
Abstract
To assess the reliability of intraocular pressure (IOP) measurement by Goldmann applanation tonometry (GAT) versus pneumotonometry in patients after laser in situ keratomileusis (LASIK) for myopia. Shiley Eye Center, University of California San Diego, La Jolla, California, USA. In this prospective study, 31 eyes of 17 patients were evaluated before and 1 month after having LASIK for myopia. A masked observer measured preoperative and postoperative IOP by GAT centrally and by pneumotonometry at the center and the periphery of the cornea. Central corneal thickness and curvature were evaluated. Preoperative IOP showed a good correlation between GAT and pneumotonometry values (r = 0.82). Mean postoperative IOP by GAT was lower by 3.8 mm Hg +/- 2.2 (SD) (26.3% +/- 15.2%) than by pneumotonometry: 2.3 +/- 2.8 mm Hg (15.4% +/- 10.7%) (P = .01). There were no statistically significant differences in central IOP versus peripheral IOP measured by pneumotonometry (P = .4). Regression analysis showed no statistically significant differences in IOP as a function of change in corneal thickness or change in corneal curvature with either device. Postoperatively, there was a decrease in IOP measured by central GAT that was statstically significant. Differences in pneumotonometry were less substantial, with greater reliability of pneumotonometry than GAT after LASIK.Keywords
This publication has 13 references indexed in Scilit:
- The Effect of Excimer Laser Photorefracti*ve Keratectomy on Intraocular Pressure Measurements Using the Goldmann Applanati-on TonometerOphthalmology, 1997
- Reduction in Intraocular Pressure after Excimer Laser Photorefractive KeratectomyOphthalmology, 1997
- Ocular Hypertension and Central Corneal ThicknessOphthalmology, 1995
- The Influence of Corneal Thickness and Corneal Curvature on Tonometry Readings after Corneal Refractive SurgeryEuropean journal of Implant and Refractive Surgery, 1995
- Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer.British Journal of Ophthalmology, 1994
- Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.British Journal of Ophthalmology, 1994
- Corneal Preservation and Eye BankingCornea, 1987
- Measurement of intraocular pressure: A study of its reproducibilityAlbrecht von Graefes Archiv für Ophthalmologie, 1976
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975
- CENTRAL CORNEAL THICKNESS IN LOW‐TENSION GLAUCOMAActa Ophthalmologica, 1974