Enhanced Characterization of Complex Proteomic Samples Using LC−MALDI MS/MS: Exclusion of Redundant Peptides from MS/MS Analysis in Replicate Runs
- 22 October 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (23) , 7816-7825
- https://doi.org/10.1021/ac050956y
Abstract
Due to the complexity of proteome samples, only a portion of peptides and thus proteins can be identified in a single LC−MS/MS analysis in current shotgun proteomics methodologies. It has been shown that replicate runs can be used to improve the comprehensiveness of the proteome analysis; however, high-intensity peptides tend to be analyzed repeatedly in different runs, thus reducing the chance of identifying low-intensity peptides. In contrast to commonly used online ESI-MS, offline MALDI decouples the separation from MS acquisition, thus allowing in-depth selection for specific precursor ions. Accordingly, we extended a strategy for offline LC−MALDI MS/MS analysis using a precursor ion exclusion list consisting of all identified peptides in preceding runs. The exclusion list eliminated redundant MS/MS acquisitions in subsequent runs, thus reducing MALDI sample depletion and allowing identification of a larger number of peptide identifications in the cumulative dataset. In the analysis of the digest of an Escherichia coli lysate, the exclusion list strategy resulted in a 25% increase in the number of unique peptide identifications in the second run, in contrast to simply pooling MS/MS data from two replicate runs. To reduce the increased LC analysis time for repeat runs, a four-column multiplexed LC system was developed to carry out separation simultaneously. The multiplexed LC−MALDI MS provides a high-throughput platform to utilize the exclusion list strategy in proteome analysis.Keywords
This publication has 16 references indexed in Scilit:
- A new method to analyze matrix-assisted laser desorption/ionization time-of-flight peptide profiling mass spectraRapid Communications in Mass Spectrometry, 2005
- High-Throughput Mass Spectrometer Using Atmospheric Pressure Ionization and a Cylindrical Ion Trap ArrayAnalytical Chemistry, 2004
- Microdeposition Device Interfacing Capillary Electrochromatography and Microcolumn Liquid Chromatography with Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryAnalytical Chemistry, 2004
- Impact of Ion Trap Tandem Mass Spectra Variability on the Identification of PeptidesAnalytical Chemistry, 2004
- A Universal Denoising and Peak Picking Algorithm for LC−MS Based on Matched Filtration in the Chromatographic Time DomainAnalytical Chemistry, 2003
- High-Throughput Miniature Cylindrical Ion Trap Array Mass SpectrometerAnalytical Chemistry, 2003
- Evaluation of Multidimensional Chromatography Coupled with Tandem Mass Spectrometry (LC/LC−MS/MS) for Large-Scale Protein Analysis: The Yeast ProteomeJournal of Proteome Research, 2002
- Global analysis of the Deinococcus radiodurans proteome by using accurate mass tagsProceedings of the National Academy of Sciences, 2002
- Shotgun Proteomics and Biomarker DiscoveryDisease Markers, 2002
- Direct Analysis and Identification of Proteins in Mixtures by LC/MS/MS and Database Searching at the Low-Femtomole LevelAnalytical Chemistry, 1997