Left-ventricular dynamic model based on constant ejection flow periods
- 1 January 1991
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 38 (12) , 1204-1212
- https://doi.org/10.1109/10.137286
Abstract
Experiments with constant ejection flow periods on the rabbit left ventricle suggest that left ventricular pressure can be described by a time varying three-element model consisting of elastance Ee(t), resistance R(t), and series-elastance Es(t). Previous experiments demonstrated the existence of a "deactivation effect" after the cessation of a constant ejection flow period, which could be described by a decrease of elastance Ee(t). This paper presents a simulation model based on findings of constant ejection flow experiments, and tested on measured pressure and volume data. The results show that when the model is fitted on one single beat, left ventricular pressure can satisfactorily be described by a three-element model without deactivation. However, the model does not predict isovolumic pressure at end-ejection volume. When isovolumic pressure has to be described by the model as well, introduction of deactivation is necessary. The quality of the model was further tested by fitting it to two beats with different ejection parameters. Deactivation again was necessary for a good fit. Only with a deactivation effect in the model, the component values found are close to the normal range found with CFP experiments in the rabbit left ventricles. From the simulation results it can be concluded that (at least for constant ejection flow periods) elastance, resistance, series-elastance, and deactivation effects all are necessary in describing (and predicting) left ventricular pressure.Keywords
This publication has 16 references indexed in Scilit:
- Deactivation in the rabbit left ventricle induced by constant ejection flowIEEE Transactions on Biomedical Engineering, 1989
- Sensitivity of left ventricular end-systolic pressure-volume relation to type of loading intervention in dogs.Circulation Research, 1988
- A computer study of the relation between chamber mechanical properties and mean pressure-mean flow of the left ventricle.Circulation Research, 1988
- Time constants for switching flow in left ventricular output impedancePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1988
- Left ventricular internal resistance and unloaded ejection flow assessed from pressure-flow relations: a flow-clamp study on isolated rabbit hearts.Circulation Research, 1987
- Source parameters of the left ventricle related to the physiological characteristics of the cardiac muscleBiophysical Journal, 1986
- Systolic mechanical properties of the left ventricle. Effects of volume and contractile state.Circulation Research, 1983
- Determinants of instantaneous pressure in canine left ventricle. Time and volume specification.Circulation Research, 1980
- Instantaneous Pressure-Volume Relationships and Their Ratio in the Excised, Supported Canine Left VentricleCirculation Research, 1974
- Parameter Estimates of a Left Ventricular Model During EjectionIEEE Transactions on Biomedical Engineering, 1973