Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure
- 1 February 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 8 (1) , 27-30
- https://doi.org/10.1097/00126097-200302000-00006
Abstract
Objective To evaluate three methods aimed at the reconstruction of brachial pressure from non-invasive finger arterial pressure measurements as implemented in the Finometer(TM), (FMS, Finapres Measurement Systems, Arnhem, Netherlands), the successor to the Finapres(TM) (TNO Biomedical Instrumentation, Amsterdam, Netherlands). Methods Finger arterial pressure (FinAP) may differ from intra-brachial pressure (BAP). Pulse shape differences are removed by applying a generalized waveform filter. Pressure level differences are corrected by a generalized level correction equation using filtered systolic and diastolic levels and by level calibration, which uses an additional return-to-flow (RTF) systolic pressure measurement on the ipsilateral upper arm for an individual calibration of the reconstructed brachial pressure. Validation These methods were validated in 37 subjects, aged 41 to 83 years after a cardiac catheterization procedure. Intra-brachial and Finometer pressures were recorded simultaneously. Finometer pressures were compared after application of waveform filtering and level correction (flcAP), and after an additional RTF calibration (reBAP). Results Finger arterial systolic, diastolic and mean pressures for the group differed from BAP by -9.7 +/- 13.0, -11.6 +/- 8.0 and -16.3 +/- 7.9 mmHg (mean +/- SD) respectively. Similarly flcAP differed by -1.1 +/- 10.7, -0.2 +/- 6.8 and -1.5 +/- 6.6 mmHg and reBAP differed by 3.1 +/- 7.6, 4.0 +/- 5.6 and 2.7 +/- 4.7 mmHg. Conclusion Reconstruction of BAP from FinAP as implemented in the Finometer reduces the pressure differences, with an individual RTF calibration to well within AAMI requirementKeywords
This publication has 7 references indexed in Scilit:
- Variable day/night bias in 24-h non-invasive finger pressure against intrabrachial artery pressure is removed by waveform filtering and level correctionJournal Of Hypertension, 2002
- A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients †British Journal of Anaesthesia, 2001
- Fifteen years experience with finger arterial pressure monitoring: assessment of the technologyCardiovascular Research, 1998
- Models of brachial to finger pulse wave distortion and pressure decrementCardiovascular Research, 1997
- Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure MeasurementsCirculation, 1996
- Computation of aortic flow from pressure in humans using a nonlinear, three-element modelJournal of Applied Physiology, 1993
- Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.Hypertension, 1993