Anterior chamber measurements using Pentacam rotating Scheimpflug camera
- 1 March 2006
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (3) , 456-459
- https://doi.org/10.1016/j.jcrs.2005.12.103
Abstract
To investigate the mean values and standard deviations according to age, reliability, and correlation between different parameters of anterior chamber measurements using the Pentacam rotating Scheimpflug camera. Heidelberg IOL and Refractive Surgery Research Group, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. This prospective clinical study comprised 76 healthy volunteers (mean age 46.6 years +/- 16.8 [SD]). Three consecutive measurements were made of only 1 eye and anterior chamber depth (ACD), mean and minimum anterior chamber angle (ACA), and anterior chamber volume (ACV) were evaluated. Mean ACD was 2.93 +/- 0.36 mm, mean ACA was 34.81 +/- 5.05 degrees, minimum ACA was 29.99 +/- 5.53 degrees, and mean ACV was 160.3 +/- 36.81 mm3. Increasing age was associated with reduced ACD and ACV; however, mean and minimum ACAs were lowest in patients aged 40 to 59 years. Excellent correlation was found between ACD and ACV (R = 0.92). Anterior chamber depth and mean ACA correlated only moderately (R = 0.65). The correlation coefficient between ACD and minimum ACA was smaller (R = 0.58). There was no correlation between ACV and ACA (R = 0.37). Minor standard deviations were noted (ACD 0.02 +/- 0.02 mm, mean ACA 1.12 +/- 0.94 degrees, minimum ACA 2.04 +/- 2.67 degrees, and ACV 2.48 +/- 1.65 mm3). Using the Pentacam, it was possible to examine different parameters of the anterior chamber within a short period and with good reliability. The evaluation of the ACA in different positions can help to classify the potential risk for angle-closure glaucoma.Keywords
This publication has 20 references indexed in Scilit:
- Reliability of Orbscan II topography measurements in relation to refractive statusJournal of Cataract & Refractive Surgery, 2005
- Zentrale und periphere Hornhautpachymetrie - Normevaluation mit dem Pentacam-SystemKlinische Monatsblätter für Augenheilkunde, 2005
- Anterior chamber depth measurement: A-scan versus optical methodsJournal of Cataract & Refractive Surgery, 2002
- Myopic angle-supported intraocular lenses Two-year follow-upOphthalmology, 2000
- Intra-observer repeatability and inter-observer agreement of the Smith method of measuring the anterior chamber depth.Ophthalmic and Physiological Optics, 2000
- Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian PopulationArchives of Ophthalmology (1950), 2000
- Biometry and Primary Angle-closure Glaucoma among Chinese, White, and Black PopulationsOphthalmology, 1997
- Achieving Emmetropia in Extremely Short Eyes with Two Piggyback Posterior Chamber Intraocular LensesOphthalmology, 1996
- Anterior Chamber Depth Measurement in Clinical PracticeOptometry and Vision Science, 1996
- Intraocular lens power calculation with an improved anterior chamber depth prediction algorithmJournal of Cataract & Refractive Surgery, 1995