Reliability of Orbscan II topography measurements in relation to refractive status
- 1 August 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (8) , 1607-1613
- https://doi.org/10.1016/j.jcrs.2005.01.013
Abstract
PURPOSE: To investigate the reliability of corneal topography measurements using the Orbscan II topography system (Bausch & Lomb) not only referring to a normal cohort but also to different refractive conditions. SETTING: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. METHODS: Eighty patients (mean age 46.4 ± 19.0 years) were assigned to 4 refractive groups (Group A: emmetropia (n = 20); Group B: astigmatism (n = 20) (−1.98 ± 1.77 diopters [D]); Group C: hyperopia (n = 20) (+4.84 ± 1.6 D); Group D: myopia (n = 20) (−9.64 ± 3.79 D). Three measurements were performed in a series. Thirteen defined, standardized points of the entire cornea (apex, 3.0 mm, 5.0 mm, and 7.0 mm zone) were evaluated for 3 different maps (anterior elevation, pachymetry, keratometry). RESULTS: In all 80 patients, the following mean values were found in relation to analyzed zones: with regard to the anterior elevation map, the values decreased from 5.53 μm (center) to −6.52 μm (7.0 mm zone), the corneal thickness increased from 549.41 μm to 638.63 μm peripheral and the keratometry from 43.86 D (apex) to 45.4 D (7.0 mm zone), respectively. Analysis of the 3 different maps in all 4 refraction groups showed a tendency toward an increase in SD from the center to the 7.0 mm zone for anterior elevation and pachymetry maps. For keratometry, however, the lowest SD was found in the 7.0 mm zone. In particular, patients with hyperopia showed significant differences (P<.01), compared with emmetropic patients; the SD was higher with regard to anterior elevation as well as keratometry in peripheral zones. Group B (astigmatism) showed significantly higher SD for anterior elevation in zones 3.0, 5.0, and 7.0 mm when compared with emmetropic patients. CONCLUSIONS: The repeated Orbscan II measurements showed SD in the micrometer range for anterior elevation and pachymetry but values between 0.48 D and 0.97 D for keratometric data. Patients with astigmatism and especially hyperopia showed significantly higher SD values in peripheral zones for anterior elevation and keratometry, indicating a lower reliability, compared with the emmetropic cohort. However, the different ages of the patients could also be a possible explanation for these findings. Therefore, the Orbscan II seems to be a predictable and useful device for measuring corneal topography.Keywords
This publication has 25 references indexed in Scilit:
- Accuracy and predictability of the compensatory function of Orbscan II in intraocular pressure measurements after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2002
- Corneal interactive programmed topographic ablation customized photorefractive keratectomy for correction of postkeratoplasty astigmatismOphthalmology, 2001
- Topography-driven excimer laser for the retreatment of decentralized myopic photorefractive keratectomyOphthalmology, 2001
- The Repeatability of Corneal Thickness MeasuresCornea, 2000
- Topography-driven photorefractive keratectomy Results of corneal interactive programmed topographic ablation softwareOphthalmology, 2000
- Keratoconus evaluation using the Orbscan Topography SystemJournal of Cataract & Refractive Surgery, 2000
- The effects of long-term contact lens wear on corneal thickness, curvature, and surface regularityOphthalmology, 2000
- Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography systemBritish Journal of Ophthalmology, 1999
- Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetryJournal of Cataract & Refractive Surgery, 1997
- Measuring anterior chamber depth with the Orbscan Topography SystemJournal of Cataract & Refractive Surgery, 1997