Global models of pulse-power-modulated high-density, low-pressure discharges
- 1 May 1996
- journal article
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 5 (2) , 145-158
- https://doi.org/10.1088/0963-0252/5/2/006
Abstract
Global (volume-averaged) models of high-density, low-pressure electropositive and electronegative discharges are described both for continuous wave (CW) and for pulsed-power excitation. Argon and chlorine discharges are treated. The particle and energy balance equations are applied to determine the charged particle and neutral dynamics. For argon just after the power has been turned on, the analysis shows an initial very sharp rise in electron temperature , followed by a decay of and an increase in the electron density to steady state values during the pulse-on time. Just after the power has been turned off, decays rapidly and decays more slowly. The time-average can be considerably higher than that for CW discharges for the same time-average power. For chlorine, a CW discharge is highly dissociated and the negative ion density is lower than . For a pulsed discharge, the initial rise and subsequent decay of just after the power has been turned off are determined analytically. A pulsed discharge can have the same neutral radical (Cl) flux to the walls for a reduced average power. The analytical models are compared to more complete global model simulations and to experimental observations. We find that global models can provide considerable insight into the discharge dynamics.Keywords
This publication has 21 references indexed in Scilit:
- etching byM= 0 helicon plasmaPlasma Sources Science and Technology, 1996
- A New Technology for Negative Ion Detection and the Rapid Electron Cooling in a Pulsed High-Density Etching PlasmaJapanese Journal of Applied Physics, 1995
- Time Variation of Plasma Properties in a Pulse-Time-Modulated Electron Cyclotron Resonance Discharge of Chlorine GasJapanese Journal of Applied Physics, 1995
- Breakdown, steady-state, and decay regimes in pulsed oxygen helicon diffusion plasmasJournal of Applied Physics, 1995
- SiO2 deposition from oxygen/silane pulsed helicon diffusion plasmasApplied Physics Letters, 1995
- Diagnostics and control of radicals in an inductively coupled etching reactorJournal of Vacuum Science & Technology A, 1995
- Pulse-time modulated electron cyclotron resonance plasma etching for highly selective, highly anisotropic, and less-charging polycrystalline silicon patterningJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 1994
- Pulse-time-modulated electron cyclotron resonance plasma etching for highly selective, highly anisotropic, and notch-free polycrystalline silicon patterningApplied Physics Letters, 1994
- Highly Selective and Highly Anisotropic SiO2 Etching in Pulse-Time Modulated Electron Cyclotron Resonance PlasmaJapanese Journal of Applied Physics, 1994
- Time-modulated electron cyclotron resonance plasma discharge for controlling generation of reactive speciesApplied Physics Letters, 1993