Multisegment and Halfscan Reconstruction of 16-Slice Computed Tomography for Assessment of Regional and Global Left Ventricular Myocardial Function
- 1 April 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (4) , 400-409
- https://doi.org/10.1097/01.rli.0000201233.42994.9b
Abstract
We sought to prospectively compare multisegment and halfscan reconstruction of 16-slice computed tomography (CT) for the assessment of regional and global left ventricular myocardial function with magnetic resonance imaging (MRI) as the reference standard. Forty-two patients underwent CT with 16 × 0.5-mm detector collimation. Electrocardiogram-gated reconstructions were generated with multisegment reconstruction (using up to 4 segments correlated with the raw data of up to 4 heartbeats) and standard halfscan reconstruction. Steady-state free-precession cine MRI was acquired within 24 hours. More normal myocardial segments were identified correctly with multisegment (95%, 620/656) compared with halfscan reconstruction (88%, 582/656) of CT (P < 0.001). Also, the accuracy (92% [657/714] vs. 87% [620/714]) and rate of nondiagnostic segments (0% vs. 5% [33/714]) were significantly better when using multisegment reconstruction (P < 0.001). The image quality with multisegment reconstruction was significantly superior to that achieved with halfscan reconstruction (P < 0.001). In the assessment of global left ventricular function, multisegment and halfscan reconstruction of CT showed high correlations for all parameters with MRI, whereas Bland-Altman analysis revealed smaller limits of agreement for assessment of myocardial mass with multisegment reconstruction (P = 0.025), but no significant differences between both reconstruction techniques in the measurement of left ventricular volumes as compared with MRI. Multisegment reconstruction of 16-detector row CT improves image quality and assessment of regional wall motion compared with standard halfscan reconstruction.Keywords
This publication has 36 references indexed in Scilit:
- Dynamic Cine Mode Imaging of the Normal Aortic Valve Using 16-Channel Multidetector Row Computed TomographyInvestigative Radiology, 2005
- Quantification of Functional Mitral Valve Regurgitation in Patients With Congestive Heart FailureInvestigative Radiology, 2004
- Performance Evaluation of a 64-Slice CT System with z-Flying Focal SpotRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Räumliche und zeitliche Auflösung für die Herzdiagnostik mit 16-Schicht-ComputertomographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Darstellung der Koronararterien mittels Mehrschicht-Spiral-CT: Optimierung der Bildqualität mittels Multisegment-Rekonstruktion und variabler Gantry-RotationszeitRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Quantifizierung der Herzfunktion in der Mehrschicht Spiral CT mit retrospektivem EKG-Gating: Vergleich zur KernspintomographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem GatingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Evaluation of left ventricular mass: Comparison of ultrafast computed tomography, magnetic resonance imaging, and contrast left ventriculographyAmerican Heart Journal, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986