Near-Infrared Spectroscopy for Dairy Management: Measurement of Unhomogenized Milk Composition
Open Access
- 1 November 1999
- journal article
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 82 (11) , 2344-2351
- https://doi.org/10.3168/jds.s0022-0302(99)75484-6
Abstract
The potential of near-infrared spectroscopy to measure fat, total protein, and lactose contents of unhomogenized milk was studied for use in dairy management, as a new tool for on-line milk analysis in the process of milking. Influence of the spectral region, sample thickness, and spectral data treatment on the accuracy of determination was investigated. Transmittance spectra of 258 milk samples, collected at different stages of the milking process, were obtained with a spectrophotometer (NIRSystems 6500; FOSS-NIRSystems, Silver Spring, MD) in the wavelength range from 400 to 2500 nm with sample thicknesses of 1 mm, 4 mm, and 10 mm. The spectral region and sample thickness were found to be significant factors for milk fat and total protein determination but not the lactose determination. The best accuracy was obtained with the 1100 to 2400 nm region, 1-mm sample thickness, and the first derivative data transformation. For the spectral region from 700 to 1100 nm, close accuracy was obtained for fat with a 10-mm sample and for total protein with a 1-mm sample thickness. The sample thickness did not change significantly the accuracy of lactose determination. Different treatments of spectral data did not improve the calibrations for fat and protein. For the region from 700 to 1100 nm, where inexpensive on-line sensors could be used, the highest positive coefficients for fat were at 930, 968, 990, 1026, 1076, and 1092 nm; for lactose were at 734, 750, 786, 812, 908, 974, 982, and 1064 nm; and for total protein were at 776, 880, 902, 952, and 1034 nm.Keywords
This publication has 12 references indexed in Scilit:
- Rapid Near Infrared Spectroscopic Screening of Chemical Parameters in Semi-hard Cheese Using ChemometricsJournal of Dairy Science, 1998
- Use of regular milking records versus daily records for nutrition and other kinds of managementLivestock Production Science, 1997
- Whey Changes during Processing Determined by Near Infrared SpectroscopyJournal of Food Science, 1997
- Comparison of sample handling and data treatment methods for determining moisture and fat in Cheddar cheese by near-infrared spectroscopyJournal of Agricultural and Food Chemistry, 1994
- Near Infrared Calibrations for Goat's Milk Components: Protein, Total Casein, αs-, β- and k-caseins, Fat and LactoseJournal of Near Infrared Spectroscopy, 1993
- Selection of Near-infrared Wavelengths for Monitoring Milk Coagulation Using Principal Component AnalysisTransactions of the ASAE, 1992
- Detection of Foreign Fat Adulteration of Milk Fat by Near Infrared Spectroscopic MethodJournal of Dairy Science, 1990
- Analysis of Milk Constituents by the Near Infrared Spectrophotometric MethodNihon Chikusan Gakkaiho, 1987
- Influence of Nutritional Factors on the Yield, Composition and Physical Properties of Milk FatPublished by Springer Nature ,1983
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964