Respiratory motion correction for PET oncology applications using affine transformation of list mode data
- 12 December 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (1) , 121-140
- https://doi.org/10.1088/0031-9155/52/1/009
Abstract
Respiratory motion is a source of artefacts and reduced image quality in PET. Proposed methodology for correction of respiratory effects involves the use of gated frames, which are however of low signal-to-noise ratio. Therefore a method accounting for respiratory motion effects without affecting the statistical quality of the reconstructed images is necessary. We have implemented an affine transformation of list mode data for the correction of respiratory motion over the thorax. The study was performed using datasets of the NCAT phantom at different points throughout the respiratory cycle. List mode data based PET simulated frames were produced by combining the NCAT datasets with a Monte Carlo simulation. Transformation parameters accounting for respiratory motion were estimated according to an affine registration and were subsequently applied on the original list mode data. The corrected and uncorrected list mode datasets were subsequently reconstructed using the one-pass list mode EM (OPL-EM) algorithm. Comparison of corrected and uncorrected respiratory motion average frames suggests that an affine transformation in the list mode data prior to reconstruction can produce significant improvements in accounting for respiratory motion artefacts in the lungs and heart. However, the application of a common set of transformation parameters across the imaging field of view does not significantly correct the respiratory effects on organs such as the stomach, liver or spleen.Keywords
This publication has 14 references indexed in Scilit:
- Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATEPhysics in Medicine & Biology, 2006
- Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PETPhysics in Medicine & Biology, 2005
- Quantitation of respiratory motion during 4D‐PET/CT acquisitionMedical Physics, 2004
- CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arraysIEEE Transactions on Nuclear Science, 2002
- Correction of the respiratory motion of the heart by tracking of the center of mass of thresholded projections: a simulation study using the dynamic MCAT phantomIEEE Transactions on Nuclear Science, 2002
- Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [18F]FDG PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2001
- Modeling respiratory mechanics in the MCAT and spline-based MCAT phantomsIEEE Transactions on Nuclear Science, 2001
- An overlap invariant entropy measure of 3D medical image alignmentPattern Recognition, 1999
- Fast calculation of the exact radiological path for a three‐dimensional CT arrayMedical Physics, 1985